Sharp AL-1651CS Benutzerhandbuch

Seite 83

Advertising
background image

AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 13

26

43

Side void amount setting
(SIDE VOID)

[Function]
When this test command is executed, the currently set code of the side void quantity is displayed (ini-
tial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side 2.0mm))

When the adjustment value is increased by 1, the side void is changed as follows:
Side void adjustment: The side void is increased by 0.5mm. (The side void of “Set value x 0.5mm”
is made.)

[Operation]

62

Energy-save mode copy
lamp setting (C-LAMP E-S)

[Function]
Used to set half-ON /OFF of the copy lamp in the pre-heat mode.

When this test command is executed, the current set code number is displayed. Enter the desired
code number and press [ENTER/START] key to save the setting.

[Operation]
The operation is similar to test command 21-01.

64

Heater control setting in
scanner mode (S-MODE
HEATER)

[Function]
When this test command is executed, the code number of the current heater control setting is dis-
played. Enter the code number corresponding to the desired heater control setting and press
[ENTER/START] key to save the setting.

[Operation]
The operation is similar to test command 21-01.

30

01

Paper sensor status display
(P-SENSOR)

[Function]
The paper sensor status is displayed on the LCD.

Since the manual paper feed sensor is a single bypass sensor, its status is not displayed.

[Operation]

Main
code

Sub

code

Contents

Details of function/operation

9

Code

Setting

Remark

0

0 mm

4

1

0.5 mm

2

1.0 mm

3

1.5 mm

4

2.0 mm

Default

5

2.5 mm

6

3.0 mm

7

3.5 mm

8

4.0 mm

9

4.5 mm

10

5.5 mm

1) Initial display

2)

[→

/10KEY]

2) [

/10KEY]

3) [ENTER/START]

26-43 SIDE VOID

4( 0-10)

26-43 SIDE VOID

5( 0-10)

26-43 SIDE VOID

3( 0-10)

26-43 SIDE VOID

5( 0-10)

Code number

Setting

Display item

Remark

0

Copy lamp OFF

OFF

1

Copy lamp half-ON

ON

Default

Code number

Heater control setting

Display item

Remark

0

Heater control OFF

OFF

Default (Only for Europe)

1

Heater control ON

ON

Default (Only for other than Europe)

Sensor

Display item

Remark

Paper exit sensor

POD

No. 1 tray paper width sensor

PD1

No. 2 tray paper width sensor

PD2

Paper entry sensor

PPD1

Duplex sensor

PPD2

No. 2 tray paper feed sensor

PPD3

New drum cartridge sensor

DRST

1) Initial display

2) When sensor ON

30-01 P-SENSOR

30-01 POD PD1 PD2

PPD1 PPD2 PPD3 DRST

Advertising