Sharp AL-1651CS Benutzerhandbuch

Seite 84

Advertising
background image

AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 14

41

06

OC cover float detection
level (OC FLOAT LEVEL)

[Function]
When this test command is executed, the current set value is displayed. When [ENTER/START] key
is pressed, the mirror base unit moves to the SPF scan position to acquire the OC cover float detec-
tion level.

When the mirror base unit returns to the home position, the acquired value is displayed.

If the detection level is not acquired, ERR display is made. (Default: 0)

Note that, this test command must be executed with the OC cover closed.

If the value is 0, float detection is not performed in normal jobs.

[Operation]

43

01

Fusing temperature setting
(Normal copy) (FU TEMP)

[Function]
When this test command is executed, the current set code number is displayed. Press [

/

/10KEY]

key to change the setting and press [ENTER/START] key to save the setting into the EERPOM. The
machine goes into the sub code entry standby mode.

[Operation]
The operation is similar to test command 21-01.

04

Fusing temperature setting
in multi coy (FU TEMP
MULTI)

[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the temper-
ature set with test command 43-1 to the temperature set with this test command.

When this test command is executed, the current set code number is displayed. Enter the code num-
ber and press [ENTER/START] key to change the setting.

[Operation]
The operation is similar to test command 21-01.

Main
code

Sub

code

Contents

Details of function/operation

1) Initial display

2) [ENTER/START]

41-06 OC FLOAT LEVEL

0

41-06 OC FLOAT LEVEL

EXECUTING...

<Canceling - when C/CA key is pressed->

After canceling, the machine goes into the sub code entry
standby mode.

3) When the level is acquired:

3) When the level is not acquired:

THE JOB IS BEING

CANCELED.

41-06 OC FLOAT LEVEL

**** OK

41-06 OC FLOAT LEVEL

**** ERR

Code

Set temperature (°C)

Remark

0

160

1

165

2

170

3

175

4

180

5

185

6

190

Default

7

195

8

200

Code

Set temperature (°C)

Remark

0

155

1

160

2

165

3

170

Default

4

175

5

180