Sharp AL-1651CS Benutzerhandbuch

Seite 86

Advertising
background image

AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 16

43

14

Fusing start temperature
setting (FU TEMP START)

[Function]
When this test command is started, the currently set code number is displayed.
Press [

/

/10KEY] to switch the setting, and press [ENTER/START] key to save it to the EEPROM.

The machine goes to the sub code entry standby mode.

[Operation]
The operation is similar to test command 21-01.

46

01

Copy density adjustment
(300dpi) (EXP.LEVEL 300)

[Function]
Copy density is set for each mode.

When this test command is executed, the current se value is displayed in 2 digits (Default: 50).

Change the set value and press [START] key to make a copy under the set value.

When the set value is increased, the copy becomes darker. When the set value is decreased, the
copy becomes lighter.

In this case, only Exp.3 copy is made. When, however, the setting is made to make darker copy,
Exp.1 and Exp.5 copies also become darker. When made to lighter copy, Exp1. and Exp.5 copies
become lighter, too.

Press [

/

] key to switch the mode. The set value of the selected mode is displayed on the LCD.

(Adjustment value: 1 – 99)

The setting procedure of the magnification ratio is the same as that to copy operation.

[Operation]

Main
code

Sub

code

Contents

Details of function/operation

Code

Set temperature (°C)

Remark

0

160

1

165

2

170

3

175

4

180

5

185

6

190

7

195

Default

8

200

Mode

Display item

Default

LED

AE mode (300dpi)

AE

50

COPY mode lamp

TEXT mode (300dpi)

TEXT

50

PRINT mode lamp

PHOTO mode

PHOTO

50

SCAN mode lamp

TS mode (TEXT)(300dpi)

TSTXT

50

PRINT mode lamp
SCAN mode lamp

TS mode (AE)(300dpi)

TSAE

50

COPY mode lamp
SCAN mode lamp

1) Initial display

2) [

] Mode selection

2) [

] Mode selection

3) [10KEY] Value entry

4) [START] Fixing and printing value (No

change on the LCD)

Print is started in the set mode.

4) To fix the set value without printing, press

[Enter] key.

To cancel manual feed paper empty MSG,
press any key.

When performing the AE mode exposure
adjustment, place the test chart on the docu-
ment table so that the center area of 10cm is
not covered.

46-01 EXP.LEVEL 300

AE 100% 50( 0-99)

46-01 EXP.LEVEL 300

TSAE 100% 50( 0-99)

46-01 EXP.LEVEL 300

TEXT 100% 50( 0-99)

46-01 EXP.LEVEL 300

AE 100% 62( 0-99)

46-01 EXP.LEVEL 300

AE 100% 62( 0-99)

46-01 EXP.LEVEL 300

AE 100% 62( 0-99)