Sharp AL-1651CS Benutzerhandbuch

Seite 99

Advertising
background image

AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 29

L1

00

Content Feeding is not completed within the specified

time after starting feeding. (The scan head
locking switch is locked)

Detail

The white area and the black marking on the
shading plate are used to obtain the difference
in the CCD level values for judgment of lock.
When the difference in the levels of which and
black is small, it is judged that the black mark
could not be scanned by lock and the trouble
code “L1” is displayed.

Cause

The scan head is locked by the lock switch.
Mirror unit abnormality
The scanner wire is disconnected.
The origin detection sensor abnormality
Mirror motor harness abnormality

Check
and
remedy

Check to confirm that the scan head lock switch
is released.
Use TC 1-1 to check the mirror reciprocating
operations.
When the mirror does not feed.
Check for disconnection of the scanner wire.
Check the harness and the connector between
the mirror motor and the MCU PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use TC 1-2 to check the mirror home position
sensor.

L3

00

Content Scanner return trouble
Detail

When the mirror base is returned for the
specified time (6 sec) in mirror initializing after
turning on the power, the mirror home position
sensor (MHPS) does not turn ON. Or when the
mirror base is returned for the specified time
(about 6 sec) after start of copy return, the
mirror home position sensor (MHPS) does not
turn ON.

Cause

Mirror unit abnormality
Scanner wire disconnection
Origin detection sensor abnormality
Mirror motor harness abnormality

Check
and
remedy

Use TC 1-1 to check the mirror reciprocating
operations.
When the mirror does not return.
Check for disconnection of the scanner wire.
Check the harness and the connector between
the mirror motor and the MCU PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use TC 1-2 to check the mirror home position
sensor.

L4

01

Content Main motor lock detection

Detail

When the main motor encoder pulse is not
detected for 100 msec.

Cause

Main motor unit abnormality
Improper connection or disconnection the main
motor and the harness.
MCU PWB abnormality

Check
and
remedy

Use TC 25-01 to check the main motor
operations.
Check connection of the main motor harness/
connector.
Replace the main motor.
Replace the MCU PWB.

Main
code

Sub

code

Details of trouble

L6

10

Content Polygon motor lock detection
Detail

The lock signal (specified rpm signal) does not
return within a certain time (about 20 sec) from
starting the polygon motor rotation.

Cause

Polygon motor unit abnormality
Improper connection or disconnection of the
polygon motor and the harness.
MCU PWB abnormality

Check
and
remedy

Use TC 61-1 to check the polygon motor
operations.
Check connection of the polygon motor
harness/connector.
Replace the polygon motor.
Replace the MCU PWB.

U2

04

Content EEPROM read/write error (Serial

communication error)

Detail

EEPROM access process error

Cause

EEPROM abnormality

Check
and
remedy

Check that the EEPROM is properly set.
Use TC 16 to cancel the trouble.
Replace the MCU PWB.

11

Content Counter check sum error (EEPROM)
Detail

Check sum error of the counter area in the
EEPROM

Cause

EEPROM abnormality

Check
and
remedy

Check that the EEPROM is properly set.
Use TC 16 to cancel the trouble.
Replace the MCU PWB.

U9

99

Content Operation panel language error

Detail

There is no language file.
The language file is destroyed.

Cause

Language file abnormality
MCU PWB abnormality

Check
and
remedy

MCU firmware download
Replace the MCU PWB.

Main
code

Sub

code

Details of trouble

Advertising