2. command details – Sony SIR-3400H Benutzerhandbuch

Seite 116

Advertising
background image

17-4

(E)

SIR-3400H / SIR-3032i / SIR-3032W

17-2. Command Details

Setting Commands

All commands use ASCII code. Each command ends with an LF (line feed), CR (carriage return) or CR

+ LF.

< >: This is the command parameter, and represents one English character.
/[ ]: This enables commands to be specified for individual recording units when multiple recorders are
connected such as during synchronous operation. The / [ ] parameter specifies any one ID number. This
specification can be omitted when only one recording unit is connected or when the target is the recording
unit with ID=0.
When performing synchronous operation with two recording units, the master is ID=0 and the subordinate is
ID=1.

Command

Contents

BAR :

Bar meter control

Command format

BAR : <1><2>/[ ]
<1> : 0=Real-time, 1=Peak hold
<2> : 0=Unidirectional, 1=Bidirectional
Ex.) BAR : 01

Real-time and bidirectional set.

BAR : 11/1

Peak hold and bidirectional set for recorders
Master=0, Subordinate=1.

Related command : BAR?

CAL :

Calibration

Command format

CAL : <1>/[ ]
<1> : 0=Calibration stop, 1=Calibration start
The results can be viewed using the CAL? command.
Related command : CAL?

CHA :

Channel mode setting

Command format

CHA : <1><2>/[ ]
<1> : Analog channel code

<2> : Digital channel code

0=OFF

0=OFF

1=RSV

1=1 ch (Async)

2=RSV

2=2 ch (Async)

3=RSV

3=4 ch (Async)

4=RSV

4=8 ch (Async)

5=16 ch (SIR-1000/1000i)

5=RSV

6=32 ch (SIR-1000/1000i/3400H/3100T)

6=RSV

7=64 ch (SIR-1000/1000i/3400H/3100T)

7=RSV

8=128 ch (SIR-1000/1000i/3400H/3100T) 8=RSV
9=RSV

9=RSV

A=RSV

A=1 ch (Sync)

B=2 ch (SIR-1000W)

B=2 ch (Sync)

C=4 ch (SIR-1000W)

C=4 ch (Sync)

D=8 ch (SIR-1000W)

D=8 ch (Sync)

E=16 ch (SIR-1000W)

E=RSV

F=RSV

F=RSV

n
Analog and digital channel modes can be used together in only certain
combinations.
In this mode, the digital channel can be set.
Related command : CHA?

FMT :

Recording media formatting

Command format

FMT : <1><2><3><4>/[ ]
<1>

: 0=RSV, 1=Formatting start

<2><3><4> : ID number at formatting (001)
n
This command logically erases all pre-recorded data.
Related command : FMT?

FTP :

Frequency type setting

Command format

FTP : <1>
<1> : 0=48 k sampling, 1=65.536 k sampling

17. Control by Telnet