Sony SIR-3400H Benutzerhandbuch

Seite 118

Advertising
background image

17-6

(E)

SIR-3400H / SIR-3032i / SIR-3032W

Command

Contents

OFS :

Input DC offset setting

Command format

OFS : <1><2>...<33>/[ ]
<1>

: Measuring unit ID number (0=Recording unit)

0=Measuring unit 1

1 to 16 CH

1=Measuring unit 1

17 to 32 CH

2=Measuring unit 2

33 to 48 CH

3=Measuring unit 2

49 to 64 CH

4=Measuring unit 3

65 to 80 CH

5=Measuring unit 3

81 to 96 CH

6=Measuring unit 4

97 to 112 CH

7=Measuring unit 4

113 to 128 CH

<2><3>

: CH 1 DC offset

<4><5>

: CH 2 DC offset

<32><33> : CH 16 DC offset
The DC offset value is expressed as a 2-digit hexadecimal number.
Ex.) OFS : 000100022334500FFCE2345220034A1FB

00 : 0 %
01 : 1 %
10 : 16 %
32 : 50 %
64 : 100 %
FF :

_1 %

CE :

_50 %

9C :

_100 %

Related command : OFS?

OPL :

Output level selection

Command format

OPL : <1><2>...<17>
<1> : Measuring unit ID number (0=Recording unit)

0=Measuring unit 1

1 to 16 CH

1=Measuring unit 1

17 to 32 CH

2=Measuring unit 2

33 to 48 CH

3=Measuring unit 2

49 to 64 CH

4=Measuring unit 3

65 to 80 CH

5=Measuring unit 3

81 to 96 CH

6=Measuring unit 4

97 to 112 CH

7=Measuring unit 4

113 to 128 CH

<2> : CH 1 output level code
<3> : CH 2 output level code

<17>: CH 16 output level code
Output level code
0=RSV, 1=RSV, 2=5 V, 3=2 V, 4=1 V, 5=RSV, 6=RSV, 7=RSV, 8=RSV, 9=RSV,
Variable values (Hex) for A=5 or higher.
Related command : OPL?

PNL :

Panel lock

Command format

PNL : <1>/[ ]
<1> : 0=Panel lock canceled, 1=Panel lock set
Related command : PNL?

RNG :

Input range setting

Command format

RNG : <1><2>...<17>/[ ]
<1> : Measuring unit ID number

0=Measuring unit 1

1 to 16 CH

1=Measuring unit 1

17 to 32 CH

2=Measuring unit 2

33 to 48 CH

3=Measuring unit 2

49 to 64 CH

4=Measuring unit 3

65 to 80 CH

5=Measuring unit 3

81 to 96 CH

6=Measuring unit 4

97 to 112 CH

7=Measuring unit 4

113 to 128 CH

<2> : CH 1 input range code
<3> : CH 2 input range code

<17> : CH 16 input range code
Input range code
0=RSV, 1=10 V, 2=5 V, 3=2 V, 4=1 V, 5=0.5 V, 6=0.2 V, 7=0.1 V
Related command : RNG?

.

.

.

.

.

.

17. Control by Telnet

.

.

.

Advertising