Sony SIR-3400H Benutzerhandbuch

Seite 126

Advertising
background image

17-14

(E)

SIR-3400H / SIR-3032i / SIR-3032W

Command

Contents

RNG?

Input range setting value readout

Command format

RNG? <1><2>/[ ]
<1> : 0=Recording unit setting value, 1=Recording media data
<2> : Measuring unit ID number

0=Measuring unit 1
1=Measuring unit 1
2=Measuring unit 2
3=Measuring unit 2
4=Measuring unit 3
5=Measuring unit 3
6=Measuring unit 4
7=Measuring unit 4

Returned format

RNG : <1><2>...<16>
<1> : CH 1 input range code
<2> : CH 2 input range code

<16> : CH 16 input range code
Input range code

0=RSV, 1=10 V, 2=5 V, 3=2 V, 4=1 V, 5=0.5 V, 6=0.2 V, 7=0.1 V

Related command : RNG

RPT?

Auto repeat status readout

Command format

RPT? /[ ]

Returned format

RPT : <1>
<1> : 0=Other than below

1=Auto repeat — recording
2=Auto repeat — rewinding

Related command : RPT

SCH?

Search status

Command format

SCH? /[ ]

Returned format

SCH : <1>
<1> : 0=Other than below (after power-on STOP command execution)

1=Search underway
2=Search finished (FOUND)
3=Search finished (NOT FOUND)

Related command : SCH

SLF?

Diagnostics status

Command format

SLF? /[ ]

Returned format

SLF : <1>
<1> : 0=Other than below (after power-on STOP command execution)

1=Diagnostics underway
2=Diagnostics finished (OK)
3=Diagnostics finished (NG)

Related command : SLF
Related command : ERR?

SPD?

Recording media speed readout

Command format

SPD? <1>/[ ]
<1> : 0=Recording unit setting value, 1=Recording media data

Returned format

SPD : <1>
<1> : 0=1

x, 1=1/2 x, 2=1/4 x, 3=1/8 x, 4=1/16 x, A=x2, B=x4, F=EXT

Related command : SPD

.

.

.