Warning

Error description Cause

Countermeasures

marks

Low DC voltage

The voltage of the external DC power

Be sure to supply the specified external DC

supply has fallen below the prescribed

voltage (11 to 30 V).

lower limit (11 V).

c
If you continue usage when this mark is displayed,
a malfunction may occur. Be sure to take the above
measures as soon as possible.

Dew condensation When the DEW function is ON,

Leave the standby key at ON. The warmup

condensation occurs in the recording

operation is performed. Wait until the mark no

media area if a cold recording unit is

longer appears before operating.

transferred to warm places.

c
. In environment where the temperature or

humidity may change, be sure to turn ON the
condensation detection function.

. To prevent media damage due to condensation

during storage, be sure to always remove the
recording media after usage, and then set the
standby key to OFF.

. Leave a space of at least 50 mm between both

sides of the unit and any other object.

LCD message

Recording unit status

Remarks

60S to 00S

Detecting the condensation

The remaining time in detecting the
condensation is displayed

Warming Up

Condensation was detected

Displayed during warmup operation

600S to 000S

Dissipating condensation

Displays the remaining time until
condensation is dissipated

Recording/Playback
error

Recording error The data supply to the recording media 1. If the mark is displayed frequently, the unit is

cannot catch up and the FIFO memory

possibly being subjected to vibrations, jolts,

becomes full. (FIFO overflow)

extreme temperatures, dust or other adverse
environmental conditions. Re-check the
installation environment.
(See section 22-1-8)

2. If the countermeasure in 1 does not fix the

problem, the recording media may be faulty.
Replace the recording media with a new one.

3. If the countermeasure in 2 does not fix the

problem, contact service engineer.

Playback error The playback data contains an error

that cannot be corrected, and re-
reading (retry) of the relevant section
was repeated. As a result, the FIFO
memory became empty, and the output
data is interrupted.
* During this retry operation, the data

remaining in the FIFO memory is
output until the correct data is read.
If the correct data is read before the
FIFO memory is emptied, playback
continues normally and the mark is
not displayed.

18. Errors and Error Messages

18-1. Warning Messages

When a malfunction occurs in the recording unit, the warning marks shown below blink in the status display
area of the LCD screen, and a buzzer will sound. Contact service engineer if the warning indicator is still
displayed after performing the measures below.