18-2

(E)

SIR-3400H / SIR-3032i / SIR-3032W

18-2. Error Code

When the recording unit malfunctions during diagnostics, calibration, recording or playback operation, the
error code is displayed on the LCD screen. Take the appropriate measure based on the table below.
When using the recorder in a dusty surrounding, the data could not be played back (or verified during
recording) and also an error code is displayed. In such a case, perform a play back inside a room. If the error
code does not disappear after the appropriate measure has been taken or if the displayed error code is not
listed in this manual, contact service engineer.

-HDD-

EH03

0C01

Drive 1 write retries have exceeded the designated limit

0C02

Drive 2 write retries have exceeded the designated limit

1101

Drive 1 read retries have exceeded the designated limit

1102

Drive 2 read retries have exceeded the designated limit

3001

Drive 1 format is not correct

3002

Drive 2 format is not correct

EH04

0001

Hard disk not installed in drive 1

0002

Hard disk not installed in drive 2

4401

Drive 1 is faulty

4402

Drive 2 is faulty

EH90

0001

Formatting of drive 1 failed

0002

Formatting of drive 2 failed

EH91

No TOC found

EH92

An invalid TOC was detected.

EH93

Communication error occurred on HDD board

EH95

Error occurred in peripherals

File system error
IDE controller error
StarFabric control error
PCI control error

EH96

An unknown error occurred

-ADA-

EA20

00xx

A/D calibration error occurred. xx is the channel.

EA30

00xx

D/A calibration error occurred. xx is the channel.

EA60

ADA flash memory error

0001

CAL data was not found

0002

Unable to access

EA70

Measuring unit ID error

EA80

ADA board error

EA90

DMA timed out in REC

EA91

DMA timed out in PB

-Power Supply/

EP03

Power failure

Battery-

EP10

Battery voltage is low

-Communication-

Ed50

Communication error occurred between the IF board and ADA
board

Ed60

Communication error occurred between the DSP board and ADA
board

Ed70

Communication error occurred between the IF board and DSP

Ed80

Telnet communication error

ES30

Error occurred between DPR board and DR board

ES40

Error occurred between DPR board and IF board

ES50

Error occurred between DR board and IF board

-Synchronizing-

EX30

Sync Setting error/cable error

EX31

Sync No target/sync playback data

EX32

Sync Recording/playback error

EX33

Sync target is recording alone

18. Errors and Error Messages