2-2. operation system, 2-3. monitor system – Sony SIR-3400H Benutzerhandbuch

Seite 151

Advertising
background image

SIR-3400H / SIR-3032i / SIR-3032W

(E)

22-5

Input

:

Connector

BNC

x 32

Input format

Direct

IEPE

Transmission format

Single-ended, Differential

Single-ended

Sensor power

24 V/4 mA

supply

(Voltage drop of constant-current
circuit is 2 V)

Input coupling

DC, AC (0.5 Hz)

AC (0.5 Hz)

Input range

±0.1, ±0.2, ±0.5, ±1, ±2, ±5, ±10 Vpk

Input DC offset

±100 % 1 % step

(During coupling DC operation
only)

Input impedance

100 k

Z

Voltage-resistance

±50 Vpk

TEDS (IEEE1451

.4) —

Support

DIRECT input — Voltage input
IEPE input — Sensor input with built-in preliminary amplifier

Output

:

Connector

BNC

x 33 (Including 1 CH monitor in unit)

Transmission format

Single-ended

Output level

±1, ±2, ±5, Variable (±0.5 to ±5) Vpk

Output impedance

50

Z

Adaptive load

Above 10 k

Z

22-2-2. Operation System

MONITOR

: Monitored channel selectable

ID No.

: Unit ID number setting (1 to 4)

22-2-3. Monitor System

Moni/ID

: Displays Monitored channel/Unit ID number

Level LED

: Simultaneous indication for 1 to 32 channels, unidirectional indicator

Power source

: POWER

Monitor

: MONITOR CH is displayed : LED on

Unit ID is displayed

: LED off

INPUT

: IEPE input

22. Specifications

Advertising