2. data playback – Sony SIR-3400H Benutzerhandbuch

Seite 99

Advertising
background image

(E)

15-3

SIR-3400H / SIR-3032i / SIR-3032W

15. Data Recording/Playback

15-2. Data Playback

1

Use BNC cables (sold separately) to connect the channel OUTPUT connectors and the analysis equipment.
A load impedance of 10 k

Ω or more is recommended.

2

Select the playback speed with the SPD/BCM key. The selected speed appears on the LCD screen.

3

Insert the recorded media into the recording unit, and press the FWD key.
This starts FWD (playback) mode and plays the data on the recording media.

The speed during recording appears in the speed display area, and the recording media position information
appears in the recording media position information display area of the LCD screen.
The input setting and recording media speed set during recording is also played back simultaneously. This
makes it easy to check the conditions set during recording.

c
. Noise may be generated if data between recording blocks is played back.
. It takes max. 2 seconds from the start of playback when to set input setting the same as the settings

recorded on the recording media.

MONITOR

UP

DN

3

2

1

Analysis equipment

Advertising