MIDI Data Format

1.2.16 NRPN (Non-registered parameter number)

This is a message for setting the sound for things like vibrato, filter or EG. Use
NRPN MSB and NRPN LSB to specify the parameter that you wish to modify,
and then use Data Entry (see 1.2.4) to set the value for the specified parameter.

Control#

Parameter

Data Range

98

NRPN LSB

0...127

99

NPRN MSB

0...127

If the Multi Part parameter Rcv NRPN = OFF, that part will not receive NRPN.

The following NRPN messages can be received.

*1 See 1.2.4
*2 “--” means that the set value will be ignored.
*3 Adjusts the time after the note is played until vibrato begins to take effect. The effect

will begin more quickly for lower values, and more slowly for higher values.

1.2.17 RPN (Registered parameter number)

This message is used to specify part parameters such as Pitch Bend Sensitivity or
Tuning. Use RPN MSB and RPN LSB to specify the parameter that you wish to
modify, and then use Data Entry (see 1.2.4) to set the value of the specified
parameter.

Control#

Parameter

Data Range

100

RPN LSB

0 ... 127

101

RPN MSB

0 ... 127

If the Multi Part parameter Rcv RPN = OFF, that part will not receive this mes-
sage.

The following RPN messages can be received.

*1 Refer to 1.2.4
*2 “--” means that the set value will be ignored.

1.2.18 Assignable controller

By assigning a control change number of 0...95 to a part, application of effects
can be controlled. This device allows two control change numbers (AC1 and
AC2) to be specified for each part.
The following parameters specify the effect of AC1 and AC2:

* Multi Part Parameter
1. AC1, AC2 PITCH CONTROL
2. AC1, AC2 FILTER CONTROL
3. AC1, AC2 AMPLITUDE CONTROL
4. AC1, AC2 LFO PMOD DEPTH
5. AC1, AC2 LFO AMOD DEPTH
The AC1 control change number is specified by the Multi Part parameter ACl
CONTROLLER NUMBER, and the AC2 control change number is specified by
the Multi Part parameter AC2 CONTROLLER NUMBER.

1.3 Channel mode messages

These messages specify the basic operation of a part.

1.3.1 All Sound Off

This message silences all notes being played on the corresponding channel.
However, channel messages such as Note-on and Hold-on will be maintained in
their present state.

Control#

Parameter

Data Range

120

All Sound Off

0

1.3.2 Reset All Controllers

This message changes the settings of the following controllers.

The following data is not changed
Parameter values specified for program change, bank select MSB/LSB, volume,
pan, effect send levels 1, 3, 4, RPN and NRPN.

Control#

Parameter

Data Range

121

Reset All Controllers

0

1.3.3 All Note Off

This message turns off all notes which are currently on for the corresponding
part.
However, if Hold 1 or Sostenuto are on, notes will continue to sound until these
are turned off.

Control#

Parameter

Data Range

123

All Note Off

0

1.3.4 Omni Off

Works the same as when All Note Off is received.

Control#

Parameter

Data Range

124

Omni Off

0

1.3.5 Omni On

Works the same as when All Note Off is received.
Control#

Parameter

Data Range

125

Omni On

0

1.3.6 Mono

Works the same as when All Sound Off is received, and if the value (mono num-
ber) is in the range of 0... 16, sets the corresponding channel to Mode4* (m = 1).

Control#

Parameter

Data Range

126

Mono

0 ... 16

* Mode4 is a state in which only channel messages on the specified channel will
be received, and notes will be played individually (monophonically).

1.3.7 Poly

Works the same as when All Sound Off is received, and sets the corresponding
channel to Mode3*.

Control#

Parameter

Data Range

127

Poly

0

* Mode3 is when channel messages will be received only on the specified chan-
nel, and notes will be sounded polyphonically.

1.4 Program change

This message is used to switch voices.
It changes the program number on the receiving channel. When the change is to
include the voice bank, transmit the program change after sending the Bank
Select message (see 1.2.1).
If the Multi Part parameter Rcv PROGRAM CHANGE = OFF, that part will not
receive program changes.

NRPN

MSB LSB

Data Entry*1

MSB LSB

Parameter Name and Data Range

01H

08H

mm

-- *2

Vibrato rate

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

09H

mm

--

Vibrato depth

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

0AH

mm

-- *3

Vibrato delay

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

20H

mm

--

Low pass filter cutoff frequency

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

24H

mm

--

High pass filter cutoff frequency

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

30H

mm

--

EQ bass gain

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

31H

mm

--

EQ treble gain

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

34H

mm

--

EQ bass frequency

mm: 04H - 28H (32 ... 2.0K [Hz])

01H

35H

mm

--

EQ treble frequency

mm: 1CH - 3AH (500 ... 16.0K [Hz])

01H

63H

mm

--

EG Attack Time

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

64H

mm

--

EG Decay Time

mm: 00H - 40H - 7FH (-64 ...0...+63)

01H

66H

mm

--

EG Release Time

mm: 00H - 40H - 7FH (-64 ...0...+63)

RPN

MSB LSB

Data Entry *1

MSB LSB

Parameter Name and Value Range

00

00H

mm

-- *2

Pitch bend sensitivity
mm: 00-18H (0...+24 semitones)
Specify up to 2 octaves in semitone steps

00

01H

mm

ll

Fine tuning
mm ll: 00H 00H -100 cents

:

:

mm 11: 40H 00H 0 cents

:

:

mm ll: 7FH 7FH +100 cents
Note: The next after mm 11: 00H 7FH (= -87.5)
cent is 01H 00H (-87.4) cents.

00H

02H

mm

--

Coarse tuning
mm: 28H - 40H - 58H (-24...0...+24 semitones)

7FH

7FH

--

--

RPN Null
This empties settings from RPN and NRPN
numbers.
Internal data is not affected.

Controller

Value

Pitch bend change
Channel pressure
Polyphonic key pressure
Modulation
Expression
Hold
Portamento
Sostenuto
RPN
NRPN

±0 (Center)
0 (OFF)
0 (OFF)
0 (OFF)
127 (Max.)
0 (OFF)
0 (OFF)
0 (OFF)
Number unset, internal data is not affected.