Monitor/remote pin layout, Xh200 – Yamaha XM4080 Benutzerhandbuch

Seite 13

Advertising
background image

14

XM4180/XM4080/XH200 Owner’s Manual

XH200

* These specifications apply to rated power supplies of 120V, 230V and 240V.

0 dBu=0.775 Vrms, Half Power=1/2 Output Power (3 dB below rated power)

Specifications and descriptions in this owner’s manual are for information pur-
poses only.
Yamaha Corp. reserves the right to change or modify products or specifica-
tions at any time without prior notice. Since specifications, equipment or
options may not be the same in every locale, please check with your Yamaha
dealer.

European models
Purchaser/User Information specified in EN55103-1 and EN55103-2.
Inrush Current: 25A
Conforms to Environments: E1, E2, E3 and E4

MONITOR/REMOTE PIN layout

Output Power*

40 Hz–20 kHz
THD+N= 0.1 %

70 V, RL=25

MIN

200 W x 2

100 V, RL=50

200 W x 2

Power Consumption

Standby

5 W

Idle

40 W

1/8 (4

Ω/Pink noise)

400 W

THD+N

40 Hz–20 kHz, Half Power

MAX

0.1 %

Intermodulation Distortion

60 Hz:7 kHz, 4:1, Half Power

MAX

0.1 %

Frequency Response

Po=1 W, HPF=40 Hz,
80 Hz–20 kHz

MAX

0 dB

TYP

0 dB

MIN

-0.5 dB

SN Ratio

(DIN AUDIO)

MIN

103 dB

Channel Separation

Half Power, 1 kHz, Att. max, input 600

Ω shunt

MIN

60 dB

Residual Noise

Att. min, (DIN AUDIO)

MAX

-65 dBu

Input Sensitivity

Att. max

TYP

+4 dBu

Voltage Gain

Att. max

TYP

38 dB (100 V), 35 dB (70 V)

Maximum Input Voltage

MIN

+22 dBu

Input Impedance

TYP

20 k

Ω (balanced), 10 kΩ (unbalanced)

Controls

Front Panel

POWER switch (push on/push off)

attenuator (31 position) x 2

Rear Panel

OUTPUT VOLTAGE switch (100 V/70 V) x 1

HPF switch (40 Hz/80 Hz 12 dB/oct) x 2

Connectors

INPUT

Euroblock connector (balanced) /ch

SPEAKERS

Barrier strip/ch

MONITOR/REMOTE

Dsub 15P x 1

Indicators

POWER/STANDBY

x 1 (Green/Orange)

SIGNAL

x 2 (Green)

CLIP/LIMIT

x 2 (Red)

PROTECT/MUTE

x 1 (Red)

Load Protection

POWER switch on/off mute

DC-fault: output relay off/restored automatically.

Clip limiting : THD

≥ 0.5 %

Amplifier Protection

Thermal: Cuts the output (when heatsink temp.

≥ 90 °C);

operation restored automatically.

VI limiter (RL

≤ 16

): Limits the output.

Power Supply Protection

Thermal: Power supply shutdown (when temp.

≥ 90 °C);

operation not restored automatically.

Cooling

Variable-speed fan x 1

Dimensions (W x H x D)

480 x 88 x 412 mm

Weight

9.8 kg

Included Accessories

Power cord, Security cover, Owner’s Manual,

3-pin Euroblock connector x 2

Pin No.

Signal

Description

1

GND

2

REMOTE CONTROL

STANDBY

STANDBY Control: Supply 5 VDC, 5 mADC

3

MONITOR

MODEL ID

XM4180: 560

Ω, XM4080: 680 Ω, XH200: 820 Ω (Impedance to GND)

4

REMOTE CONTROL

MUTE CH D

MUTE Control: Connect to GND, +5 V, 1 mA

5

MUTE CH C

6

MUTE CH B

7

MUTE CH A

8

MONITOR

PROTECT STATUS CH D

PROTECTION Off/ Output On: +5 VDC, Zo=270

PROTECTION On/ Output Off: 0 VDC, Zo=High

9

PROTECT STATUS CH C

10

PROTECT STATUS CH B

11

PROTECT STATUS CH A

12

OUTPUT LEVEL CH D

XM4180, XM4080
+4dBu (-27.2 dB of Speaker Output Level) at 100 W/8

Ω, RL=7.5 kΩ, Zo=300 Ω

XH200
-33.2 dB of Speaker Output Level, RL=7.5 k

Ω, Zo=300 Ω

13

OUTPUT LEVEL CH C

14

OUTPUT LEVEL CH B

15

OUTPUT LEVEL CH A

42

Advertising