Cleaning the air filter, Fitting the lens cap – Sony VPL-HW50ES Benutzerhandbuch

Seite 78

Advertising
background image

78

• Be sure to use an LMP-H202 Projector Lamp

for replacement. If you use lamps other than
the LMP-H202, the projector may
malfunction.

• Be sure to turn off the projector and unplug

the power cord before replacing the lamp,
then check the ON/STANDBY lamp has
already been turned off.

• The projector will not turn on unless the lamp

is securely installed in place.

• The projector will not turn on unless the lamp

cover is securely closed.

• To cancel a message displayed on the screen,

press either the button on the remote control
or the one on the control panel on the
projector.

Disposal of the used lamp

For the customers in the USA
Lamp in this product contains mercury.
Disposal of these materials may be
regulated due to environmental
considerations. For disposal or
recycling information, please contact
your local authorities or the
Telecommunications Industry
Association (www.eiae.org).

Mettre à disposition de la lampe
usagée

Pour les clients aux États-Unis
La lampe dans ce produit contient du
mercure. La disposition de ces
matériaux peut être réglementée suite à
des considérations environnementales.
Pour obtenir des informations de
disposition ou de recyclage, veuillez
communiquer avec vos autorités locales
ou la Telecommunications Industry
Association (www.eiae.org).

Cleaning the Air
Filter

When “Please clean the filter.” appears on
the screen, you should clean the air filter.
The air filter should be cleaned every 1,500
hours. This value varies depending on the
environment or how the projector is used.
1,500 hours are approximate.
After washing the air filter with a mild
detergent solution, dry it in a shaded place.

• When you clean the air filter, make sure you

do not damage it.
For details on how to attach and remove the
air filter, see “Replacing the Lamp and the
Air Filter and Cleaning the Ventilation Holes
(intake)” Steps 7 to 10. (

1 page 77)

• When you remove the air filter, be careful

not to let any dust fall into the projector.

• Cleaning the air filter is crucial to maintain

the good performance of the projector or to
prevent malfunction to it. When a warning
message for cleaning the air filter appears,
clean the air filter immediately.

Fitting the Lens Cap

When fitting the lens cap onto the lens,
position the lens cap so that the concave on
the side of the lens cap will fit the zoom
lever, as shown in the illustration.

Notes

Note

The lamp contains mercury. The disposal
rules for used fluorescent tubes depend on
where you live. Follow the waste disposal
policy in your area.

Notes

Lens cap

Zoom lever