Eliminating faults

Fault

Possible cause

Remedy

Uneven movement of
slide

No lubrication

Lubricate (see chapter Maintenance)

Restrictors incorrectly
inserted

If possible, restrict exhaust

Dirt on guides

Clean, provide cover

Guide damaged

Return for repairs, inform Festo

Slide strikes too hard
against end stops

Not enough cushioning

Increase end position cushioning (e.g.
with shock absorbers)

Delay too small/too late

Change delay (e.g. by adapting drive
control/positioning of the proximity
switch)

Speed too high

Reduce speed

Work load too large

Reduce work load

Slide vibrates with
long strokes

Speed too high

Reduce speed

Work load too large

Reduce work load

Not enough supports

Use centre supports

Other interference

Defect on integrated
linear drive

See operating instructions for the
integrated linear drive

Fig. 46