1 control sections and connections, 2 function and application, 3 requirements for product use – Festo EGC-...-2H-PN Benutzerhandbuch

Seite 3: 4 installation, Dgc(i) h-pn, egc h...-pn, egc h-pn

Advertising
background image

DGC(I)-...-1H-PN,

EGC-...-1H...-PN, EGC-...-2H-PN

Festo AG & Co. KG
Postfach
73726 Esslingen
Germany
+49 711 347-0
www.festo.com

Operating instructions

8028327
1307a
[8029217]

Original: de

Linear drive with clamping unit DGC(I)-/EGC-...-...H...-PN

English

. . . . . . . . . . . . .

Note

Installation and commissioning are to be carried out only by qualified personnel
in accordance with the operating instructions.

1

Control sections and connections

Clamping unit for DGC(I)

4

5

1

2

3

6

7

Clamping unit for EGC

4

6

5

1

6

3

2

7

1 Clamping unit:

1-channel: DGC(I)/EGC-...-1H...-PN
2-channel: EGC-...-2H-PN

2 Housing cover

3 Linear drive:

pneumatic with DGC(I)
electric with EGC

4 Guide rail

5 Lubrication hole

1)

:

- for DGC(I) accessible on 2 sides
- for EGC accessible on 3 sides

6 Supply port of the clamping unit

1)

7 Spring casing

1)

for 2-channel clamping unit EGC-...-2H-PN on both sides of the slide

Fig. 1

2

Function and application

In the pressureless status, the spring force acts on the internal mechanical system.
As a result, the contact profiles are pressed with great force against the free
surfaces of the guide rail - the slide is held in place.
Pressurizing at the supply port

6 results in the pressure force counteracting the

spring force and the contact profiles release from the guide rail - the slide is freely
movable.

DGC(I)-25/32, EGC-80

DGC(I)-40/50, EGC-120/185

Fig. 2

The clamping unit at the linear drive is intended for the following application:
– In the case of DGC(I)-25/32 and EGC-80:

holding the effective load in place (e.g. with vertical mounting orientation).
Foreseeable misuse:
Braking of a movement is not permissible. Increased wear leading to complete
failure is possible.
In the event of sudden pressure failure, further use of the clamping unit is per-
missible only if followed by a functional test (

Operation).

– For EGC-120/185 and DGC(I)-40/50:

braking of a motion sequence is permissible under certain operating conditions
(

Technical data).

3

Requirements for product use

Note

Incorrect handling can lead to malfunctioning.
• The instructions of the DGC(I)/EGC user manual must be observed for safe

use of the product.
The technical data of the linear drive with clamping unit
DGC(I)/EGC-...-...H...-PN may restrict the specifications for the DGC(I)/EGC
linear drive in the operating instructions.

Note

When used in safety-oriented applications, additional measures are required
dependent on the required safety level. These measures must be established in
the risk assessment of the machine.

• Make sure that, after pressurization of the clamping unit, no uncontrolled move-

ments can occur at the linear drive.
To ensure a sufficiently short reaction time for clamping, a suitable valve must
be selected for the air vent (

catalogue specifications).

• Use the product without any unauthorized modifications.
• Note the warnings and instructions on the product and in the relevant operating

instructions.

4

Installation

For DGC(I)-50-KF-YSR(W)-1H-PN:
• Observe the revised space of the shock ab-

sorber.
The value is: d = 47.3 ... 56 mm.

Fig. 3

• Make sure there is sufficient space for the pneumatic connections as well as

their tubing connections.

1. Remove the blanking screw from the supply port

6 to be used on each clamp-

ing unit.

2. Insert a push-in fitting into the supply port

6.

The tightening torque is 0.5 Nm.

Note

When changing the supply port:
• Insert the blanking screw into the open supply port

6.

The tightening torque is 0.5 Nm.

• Secure and seal the fitting with Loctite 222

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: