9 technical data, 1 technical data - electrical ratings (og 60), 2 technical data - electrical ratings (ogs 60) – Baumer OGS 60 Benutzerhandbuch
Seite 28: Technical data, Technical data - electrical ratings (og 60), Technical data - electrical ratings (ogs 60)
25
Baumer_OG60-OGS60-T1_II_DE-EN (14A1)
MB185T1 - 11072301
9
Technical data
9
Technical data
9.1
Technical data - electrical ratings (OG 60)
• Voltage supply:
9...26 VDC (HTL, TTL - version R)
5 VDC ±5% (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
200...10000 (As precised on order)
• Phase shift:
90° ±8°
• Duty cycle:
46...54 %
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤250 kHz
• Output signals:
A+, B+, R+, A-, B-, R-
• Output stage:
HTL, TTL/RS422 (As precised on order)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, RoHS, UL approval / E256710
9.2
Technical data - electrical ratings (OGS 60)
• Voltage supply:
5 VDC ±10 % (version DN ...)
9...26 VDC (version DN ... R)
• Consumption w/o load:
≤90 mA
• Sinewave cycles per turn:
1024...2048 (As precised on order)
• Phase shift:
90°
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output signals:
A+, B+, R+, A-, B-, R-
• Output stage:
SinCos 1 Vpp
• Difference of SinCos amplitude: ≤20 mV
• Harmonics typ.:
-50 dB
• DC offset:
≤20 mV
• Bandwidth:
250 kHz (-3 dB)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, RoHS, UL approval / E256710