Adjustment with pneumatic cushioning for DRQD−...−PPVJ

Note
S Be sure to comply with the specifications

for the safety components:
ć Do

not remove retaining rings

(for DRQD−16 ... 32).

ć Turn in the threaded sleeve until it is

completely flush to the lock nut
(for DRQD−40/50).

The safety components are used to limit
the maximum permissible rotation angle
setting. Impermissible handling of the
safety components makes it possible to
turn in the threaded sleeve too deeply.

For adjustment of the end positions:

1. Turn the moveable mass into an end posiĆ

tion by hand.

2. Loosen the lock nut of the threaded sleeve

(only for DRQD−40/50)

3. Screw in the respective threaded sleeve

with an Allen key until the desired end
position adjustment has been reached.

Fig. 14

DRQD−16−...−32

DRQD−40/50

Fig. 15