DIGITAL SYSTEM AMPLIFIER

16 Owner‘s Manual

Controls and Connections

1 INIT button

The INIT button allows resetting the RCM-810 to factory settings. Press the button for at least 3 seconds
using e.g. a small screwdriver. Table 4.1 lists the factory settings of the RCM-810 module.

2 CAN ADDRESS Selector Switch

The two address selector switches are for setting the network address of the RCM-810. CAN networks
support addresses in the range of 01 to 250 (FA hex). Addressing has to be carried out in the hexadecimal
number system. The LOW selector switch sets the lower digit, while HIGH sets the higher digit.

Address 0 (00 hex, delivery status) disables remote communication between the RCM-810 and the bus. The module does not
appear in the system, even though it is physically connected to the CAN-bus.

Illustration 4.1: Controls and Connections of the RCM-810

CAUTION:
All RCM-810 parameters configured via IRIS-Net are discarded when pressing the INIT
button.

Parameter

Value

CAN-Bus data rate

10 kbit/s

Power-On-Delay

0 ms

Amplifier & Channel Labels

RCM-810 Module, RCM-810 Input, RCM-810 Output

Supervision

not configured

Control Ports and Job Numbers

not configured

VLD

deactivated

Table 4.1: Factory Settings of RCM-810

CAUTION:
Each address may exist only once in a system. Otherwise, network conflicts may arise.

HIGH

LOW

Address

HIGH

LOW

Address

0

0

Stand-alone

8

0...F

128...143

0

1...F

1...15

9

0...F

144...159

1

0...F

16...31

A

0...F

160...175

2

0...F

32...47

B

0...F

176...191

3

0...F

48...63

C

0...F

192...207

4

0...F

64...79

D

0...F

208...223

5

0...F

80...95

E

0...F

224...239

6

0...F

96...111

F

0...A

240...250

7

0...F

112...127

F

B...F

reserved

Table 4.2: CAN addresses