Important

This quick start manual is only intended for use by professional installers who have
an adequate working knowledge of video systems!
This manual outlines the most important information about the SIMATRIX NEO
Alarm box. It is, however, vital that you also refer to the detailed information in the
full operating instruction of SIMATRIX NEO.

Installation and set-up

Step 1: Provisionally connect the SIMATRIX NEO to the electrical supply
Required power supply: TN network (to VDE 0100, section 300 or EN 60950)
Voltage range: 110 - 240 Volt
Once the system has been connected to the electrical supply, and assuming the
device is in good operating the LED at the front of the unit will lit.
To continue installation, you must now unplug all NEO components at the mains!

Step 2: establish SysLink-connection
Use the marked

SysLink-cable to connect the SysLink-input of Alarm box

(SIMNEO-A128) to the

SysLink-output of SIMATRIX NEO main or extension bay.

In case a second alarm box has to be installed, connect

SysLink-input to SysLink

output of first alarm box.

Step 3: setup device adress
First alarm box must be set to device address „2“, the second alarm box must be set
to address „3“.

Step 4: set config-switch
In case the alarm box is the last device on SysLink-Bus, the switch

R must be set

to

On, all other terminations must be switched Off. In case the device is not at the

end of the SysLink-Bus, all switches must be set to

Off.

Step 5: change alarm base parameters
Control software: Alarm base parameters button
Alarm sensor settings

Step 6: Alarm sensor to camera allocation
Control software: Sensors / Camera groups button

Step 7: Further programming
If applicable, enter further parameters in order to tailor the function of the SIMATRIX
NEO to suit individual operating needs and the rest of the system.

Step 8: Make a back-up of the parameter settings and store the back-up close
to the system.

Operation and storage

Do not operate or store the unit in following locations:

Extremely hot or cold places

Close to sources of strong magnetism

Close to sources of powerful electromagnetic radiation such as radios or TV

transmitters.

In humid or excessively dusty places

Where exposed to mechanical vibrations.

Care and maintenance

The alarm box is maintenance-free.
Use a clean soft piece of cloth to wipe small amounts of dirt or dust from the body.

Specifications

Alarm Inputs:

128 Alarm Inputs, (4 x 32 Inputs)

Input resistance:

2,2 Kilo Ohm

Threshold:

2,5 V DC

Max. voltage:

internal pull-up (max. 24 V DC external)

Alarm pulse:

min. 300 milliseconds

Length Alarm-cable:

max. 10 m

Connection Alarm:

4 x 37-pin Sub-D

Controller

1 RISC-Controller

Interface

SysLink

Power requirement

115 / 230 VAC (+10% / -15%), 50/60 Hz

(internal switchable)

Fuse

2 x 125 mA slow

Power consumption

3 VA

Operating temperature

+ 5 °C to 45 °C

Relative humidity

30 to 85 %, non condensing

Construction:

19 inch chassis

, 1 HU

Dimensions (W x H x D): 449 x 44 x 206 mm (without 19” mount)

D

a

ta

a

n

d

d

e

s

ig

n

s

u

b

je

c

t

to

c

h

a

n

g

e

w

it

h

o

u

t

n

o

ti

c

e

©

2

0

0

5

S

ie

m

e

n

s

B

u

ild

in

g

T

e

c

h

n

o

lo

g

ie

s

:

F

ir

e

a

n

d

S

e

c

u

ri

ty

P

ro

d

u

c

ts

Advertising