Package contents

• Dome camera
• 1 BNC connection cable
• 1 service monitor cable
• 2 fixing screws
• 2 wall plugs
• Fixing template
• Installation and operating instructions (this

document)

Dome camera parts

See figures A and B.
1. Cable entry holes
2. Unit casing
3. Dome casing
4. Zoom lever/locking screw
5. Focus lever/locking screw
6. Iris LEVEL screw
7. V phase adjustment screw
8. Mode setting DIP switches
9. Monitor output
10.Unit mounting holes
11.BNC connector
12.Power connector
13.Locking ring
14.Panning adjustment wheel
15.Axial ring

Installing the camera

Step 1: Connecting the cables

1. Connect the BNC cable to the BNC connector

(11).

2. Connect the power supply cable to the power

connector (12).
You can use 24 V AC or 12 V DC connection.

Caution
If using a DC supply, make sure the polarity is
correct. Incorrect connection may cause
malfunction and/or damage to the video
camera.

3. Guide the cables through the cable entry holes

(1).

Step 2: Mounting the camera

1. Place the template on the mounting surface

and mark the holes.

2. Drill two holes as marked.
3. Insert the wall plugs into the holes.
4. Fasten the unit with the screws provided.

Step 3: Adjusting the camera position

1. Hold the lens so that it does not rotate.
2. Loosen the locking ring (13) and panning

adjustment wheel (14).

Caution
Do not loosen the locking ring without holding
the lens in place. Otherwise the lens may rotate
with the locking ring and the cable may twist.

3. Turn the lens and axial ring (15) in the desired

direction.

Note
If the camera does not rotate smoothly, loosen
the locking ring completely. The locking ring has
an internal stop and will not come off.

Caution
Do not turn the lens more than 360° as this may
cause internal cables to disconnect or break.

4. Lightly tighten the locking ring (13) and panning

adjustment wheel (14)

Step 4: Adjusting zoom and focus

1. Loosen the zoom lever/locking screw (4) by

turning it counter-clockwise.

2. Rotate the zoom ring to achieve the desired

picture.

3. Loosen the focus lever/locking screw (5) by

turning it counter-clockwise.

4. Rotate the focus ring to adjust the focus.
5. If readjustment is necessary, repeat the steps

above.

6. Retighten the zoom lever/locking screw (4) and

the focus lever/locking screw (5).

Caution
Retighten the locking screws to prevent loss of
adjustment.

7. Hold the lens and tighten the locking ring (13)

and panning adjustment wheel (14).

Optional settings

• Adjust the brightness of the picture using the

LEVEL screw (6):
L = low, makes the picture darker
H =high, makes the picture brighter

• Adjust the phase difference between cameras

(use V Phase adjustment screw (7).

• Set DIP switches (8) to activate or deactivate

the following features:
• Backlight compensation (BLC)
• Automatic gain control (AGC).

Automatically adjusts the picture to suit
ambient brightness

• Line Lock (LL).

Sets camera synchronisation to internal
(OFF) or line lock (ON). Line lock is only
available with 24 V AC.

The DC/AES DIP switch is not in use.

Step 5: Attaching the dome to the unit

Note
Use a soft lint-free cloth to wipe the dome cover
clean and remove fingerprints.

1. Clean the joint surfaces of the unit.
2. Place the dome on the unit (see figure C).
3. Turn the dome clockwise and lock the cover in

place.

General guidelines

Operation and storage

• Avoid filming very bright objects (such as light

fittings) for an extended period.

• Do not operate or store the unit in the following

locations:
• Extremely hot or cold places.
• Close to sources of strong magnetism.
• Close to sources of powerful

electromagnetic radiation, such as radios or
TV transmitters.

• In humid or excessively dusty places.
• Where exposed to mechanical vibrations.
• Close to fluorescent lamps or objects

reflecting light.

• Under unstable or flickering light sources.

Cleaning

• Use a soft, dry cloth to remove fingerprints or

dust from the dome.

• If the dome is very dirty, use a small amount of

mild detergent on a damp cloth for cleaning.
Ensure the dome is dry before attaching the
dome to the unit.

Caution
Do not use volatile solvents such as alcohol,
benzene or thinners. These solvents may
damage the surface.

Transportation

Use the original packing material or materials of
equal quality.

CCD characteristics

The following conditions may be observed when
using a CCD camera. These are inherent of the
design and do not stem from any fault within the
camera itself.
• Vertical smear: This phenomenon occurs when

viewing a very bright object.

• Patterned noise: This is a fixed pattern which

may appear over the entire monitor screen
when the camera is operated at a high
temperature.

• Jagged picture: When viewing stripes, straight

lines, or similar patterns, the image on the
screen may appear jagged.

Specifications

General
Power requirement......12 V DC or 24 V AC

(Min. 5 W)

Power consumption ....3 W (max.)
Operating temperature-10 to +50°C, 90% RH max.
Storage temperature ...-20 to +60°C, 70% RH max.
External dimensions....112 x 97.5 mm
Weight in kg ................Approx. 0.29
Unit material................ABS (30%) and

polycarbonate (70%)

Dome material.............Polycarbonate

Imaging system
Imaging device............Interline transfer ¼ inch

CCD

Effective picture elements

CCIR: 752(H) * 582(V)

TV system ...................CCIR: 2:1 Interlace,

15.625 kHz horizontal,
50 Hz vertical

Optical system and other specifications
Focal length ................f=2.8 to 5.8 mm
Maximum relative aperture

F1.4

Viewing angle .............Horizontal: 76.7° (wide

angle) - 38,2° (telescopic)
Vertical: 56.8° (wide angle)
- 28.7° (telescopic)

Minimum object distance

20 cm

Synchronisation system

Internal or Line lock (24 V
AC only)

Horizontal resolution ...580 TV lines
Minimum illumination ..0.2 lx (AGC ON, more than

50% of image output r =
0.45, without dome cover)

Video output................1.0 Vp-p 75 Ohm
Video S/N ratio............More than 50 dB (AGC

OFF, Weighted)

AGC ............................ON/OFF switchable
BLC .............................ON (Center measured) /

OFF switchable

Information

This equipment has been tested and found to
comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when the equipment
is operated in a commercial environment.

This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and
used in accordance with the instruction manual,
may cause harmful interference to radio
communications. Operation of this equipment in a
residential area may cause harmful interference in
which case the user will be required to correct the
interference at his own expense.

English

Dat

a and design subject to change without notice.

© 2003 Siemens Building

Technologies: Fire and Security Product

s

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: