WTC 600 LP / MP

4

Maintenance and Care

Version 06/05

3

Maintenance and Care

3.1

Starting Operation

Before starting operation:

• Make sure that the equipment is connected to

the untreated water source and the respective
transporting gear, e. g., admission-pressure
unit.

• Ensure the unrestricted flow of the drinking water

into a tank or a suitable device on the user side.

3.1.1

Admission-pressure Unit

The admission-pressure unit consists of a
pump (21) and a control device (22). The operat-
ing condition of the pump is indicated with three
indicator lights:

• Green (24):

Ready for operation

• Yellow (25):

Pump delivering

• Red (26):

Malfunction or water low

• The reset button (23) starts the pump after fail-

ure

3.1.2

Filling the Metering Stations

• Put on protective clothing.

• Open the lid (27) of the metering station (30).

• Fill the respective chemical into the metering

station according to Section 3.2.6.

• Add the corresponding amount of chlorine-free

drinking water.

• Shut the lid of the metering station.

• Pull the mixing rod (28) out of the metering

station to the stop and push back in again.
Repeat this procedure for approx. 5 minutes
until the chemical is completely mixed.

The equipment may be put into operation only when set-up, installed and prepared for oper-
ation by an authorized KÄRCHER specialist dealer.

The drinking water must be able to run
off without counterpressure. The height
difference must not exceed 3 m.

i

In case an admission-pressure unit
is necessary, it will be installed by a
Kärcher service technician.

21

22

23

24

25

26

i

If the system is equipped with one or
more metering stations, it must be en-
sured that these are correctly filled and
connected.

The metering stations must not be
mixed up or mistaken, meaning filled
with the wrong chemical.

27

28

29

30