Noises – AEG S83600CSW1 Benutzerhandbuch

Seite 43

Advertising
background image

1

2

3

6

5

4

• Remove the handle. Unscrew the top

handle bracket from the handle rod
(1). Unscrew the bottom handle brack-
et from the door (2)

• Unscrew the top handle bracket from

the door (3).

• Re-screw the handle bracket on the

door (4). Turn the handle bracket with
the handle and screw them to the
door (5) and the fitted handle bracket
(6).

1

2

1

2

1

2

3

4

• Remove using a tool the cover. (1).
• Unscrew the upper hinge pivot (2) and

place it on the opposite side.

• Re-screw the upper hinge.
• Fit the upper door on the upper door

pivot.

• Re-insert the upper door on the mid-

dle hinge pivot (3 )slightly tilting both
doors.

• Re-screw the middle hinge. Do not

forget the plastic spacer.

Do a final check to make sure that:
• All screws are tightened.
• The magnetic seal adheres to the cab-

inet.

• The door opens and closes correctly.
If the ambient temperature is cold (i.e. in
Winter), the gasket may not fit perfectly
to the cabinet. In that case, wait for the
natural fitting of the gasket.
In case you do not want to carry out the
above mentioned operations, contact
the nearest After Sales Service Force.
The After Sales Service specialist will car-
ry out the reversibility of the doors at
your cost.

9. NOISES

There are some sounds during normal
running (compressor, refrigerant circula-
tion).

ENGLISH

43