Connection configuration of the temp
controller 8625

Fig.: Connection configuration 8625

PE

Valve output

not used

GN

24

24

Te
PT

PT
(0

GN

St
inp

PE

Do not connect any voltages to Terminal 3

Terminal 3 is a 0.5 mA output for supplyin
(PT 100).

Connection configuration of the
flow pressure controller 8624

Fig.: Connection configuration 8624

PE

Valve output

not used

_ GN
_

24

_

24

_

GN

_

Pre
inp

GN

Sta
inp

PE

Do not connect any voltages to Terminal 5

Terminal 5 is a 24 V output for supplying t
(e.g., 2-wire transmitter).

Connection configuration of the
flow controller 8623

Technical Data 8625

Inputs
Sensor inputs

PT 100

Temperature range

-100 °C to +500 °C

1)

/ -148 °F to 932 °F

Scaling 50° steps

Resolution 0,3 °C

1)

bzw. 0,54 °F

Accuracy 1 °C

1)

bzw. 1,8 °F

Scaling 100° steps

Resolution 0.5 °C

1)

bzw. 0.9 °F

Accuracy 1.5 °C

1)

bzw. 2.7 °F

External set-value input

Standard signal input 4 - 20 mA

Connection

in unit: 7-pole terminal + PE;
wire cross-section max. 0.5 mm

2

PG 9 fitting; cable ø 6 - 7 mm

Controller
Control algorithm

PI-Controller

Sampling time T

A

50 ms

Amplification factor K

P

0 - 99.99

ntegral action time T

N

0.1 - 199.99 s

22 Temperature range
Scaling of the standard signal
Heating or cooling
Device Order No. 134 074 M
Control unit type 8625-B (temperature) Order no. 134 054 R

Technical data 8624

Inputs
Signal inputs

2 standard signal inputs 4 - 20 mA

Accuracy

± 1 % of full scale

Connection

in unit: 7-pole terminal + PE;
wire cross-section max. 0.5 mm

2

PG 9 fitting; cable ø 6 - 7 mm

Controller

Control algorithm

PI-Controller

Sampling time T

A

30 ms

Amplification factor K

P

0 - 99.99

Integral action time T

N

0.1 - 199.99 s

K-faktor 1 and 2

0.0 - 1999.9

Ratio

0.01 - 9.99

Calibration

0 - 199.99

Device Order No. 134 073 L (4-20 mA)
Device Order No. 140 317 F (0-10 V)
Control unit type 8624-B (pressure) Order No. 134 053 Q

Technical data 8623

General technical data
for controllers 8623, 8624 and 8625

Operating voltage

24 V DC

Power consumption

max. 1.5 W

Output current

max. 1.0 A

Operating temperature

-10 ... +60 °C / 14 °F ... 140 °F

Interference resistance

to EN 50082-2

Interference emmission

to EN 50081-2

Output
Cable outlet

can be turned in 90° steps

Number of terminals

2 poles and earth

Type of contact

Surface contact, similar to a flat plug
(DIN 46 247/48)

Housing
Degree of protection

IP 65

Material

polyamide

Mounting

M3 x 45 mm cheesehead screws

Dimensions / Weight

32 x 90 x 41.5 mm / approx. 50 g

Inputs
Signal inputs

2 frequency inputs 2 to 625 Hz

Accuracy

± 1 %

Type of signal

sine, square, triangle (

300 mV

ss

)

1 Standard signal input

4 - 20 mA

Connection

in unit: 7-pole terminal + PE;
wire cross-section max. 0.5 mm

2

PG 9 fitting; cable ø 6 - 7 mm

Controller

Control algorithm

PI-Controller

Sampling time T

A

40 ms

Amplification factor K

P

0 - 99.99

integral action time T

N

0.1 - 199.99 s

K-factors 1 and 2

0.0 - 1999.9

Ratio

0.01 - 9.99

Calibration

0 - 199.99

Device Order No. 134 072 K

Control unit type 8623-B (flow) Order No. 134 052 P

Interference with the device is only allowed by specialist
personnel using suitable tools! Before interfering with the

controller, always switch off the voltage!

Commissioning

➔ Connect the calble.

(see Figs. under Connection Configuration)

➔ Put on the lid of the control unit.

➔ Plug the controller (flow, pressure or temperature) onto the

valve.

➔ Screw the controller tight.

When screwing the controller to the proportional valve,
ensure that the seal is properly seated!

1)

Calibrated with 1 m

line length and
0.5 mm

2

pipe cross-

section

Fig.: Connection configuration 8623

PE

Valve output

not used

_

GND

_

24 V DC

_

24 V DC output

_

Frequency input 1

_ GND
_

Frequency input 2

_

Standard signal
input 4 - 20 mA

PE

Do not connect any voltages to Terminal 5!

Terminal 5 is a 24 V output for supplying the flow sensor
(e.g.,Type 8020 with Hall sensor).

reas and function

TECHNICAL DATA

TECHNICAL DATA

INSTALLATION / COMMISSIONING

INSTALLATION / COMMISSIONING

t to make technical changes without notice.

niature controllers, in combination with

ves, serves to control

piping

(Flow rate controller 8623)

uids and

(Pressure controller 8624)

ature of

(Temperature controller 8625)

oportional valves

023, 6223, 2832, 2834

h adjustable PI control behaviour

ion on the valve, thanks to compact design of

on of a proportional valve

fication via standard signal 4-20 mA

of flow rate by means of a flow rate sensor with

put (frequency proportional to flow rate)

ensors with frequency output of max. 625 Hz
and display control unit Type 8623-B

ontrol

of the pressure by means of a pressure

h standard output signal

and display control unit Typ 8624-B

of the temperature by means of a PT 100 sensor

ng

and display control unit Typ 8625-B