Start-up submenu (standard), Start-up submenu (standard) 4.4.2 – Burkert Type 8681 Benutzerhandbuch

Seite 23

Advertising
background image

23

Software for Smartphone / PC

start-up submenu (standard)

4.4.2.

Type 8681 – Communicator

Rev. 2.4.0.0

Start-Up

Autotune 2

Autotune 1

Autotune 3

Autotune 4

Autotune 5

Autotune 6

Manual Control active?

Service indication active?

Parameter

Time

Cycles

Standard

Ranges

TEACHRESET DEV RESET

Use of external Ini S4

Opener

Closer

Screen: Start-up - Standard

By clicking on the �Autotune x” button, a description of the Autotune

function as well as the buttons

and

are indicated first

(details on the Autotune functions - see table below or in the operating
instructions)
don’t change the menu whilst the autotune process!

Set-up if

external initiator will be used as Opener (NC) or Closer (NO) -

according to the chosen external initiator

Indicates whether/which

service indication is active,

the service notification can be selected: after an elapsed time or after
elapsed cycles/switching operations or inactive (inactive = no ).
Click on the �Parameter� button to access the �Service� menu - see
description there - press the back arrow there to return to the �Start-up -
Standard� menu.

Indicates whether

manual control function is active, i.e. the

control head can be switched by magnetic manual actuation (valve 1).

“teacHreset”

button: after a warning message (

or

) all

teach positions are set to �not taught�.

“deV reset”

button: after a warning message (

or

) the

following values are reset to “0” (or �not taught”) with device reset:
- all Teach positions,
- the switching operations (cycles) counter V1-3,
- the operating-hours counter;
the standard values are reset:
- all tolerance values of the feedback areas of the position measuring
system
- the external initiator/proximity switch (as NO contact)
- manual actuation function (active)
- service notification time + switching operations (each inactive)
- parameter maintenance (V1=10000, V2=50000, V3=50000; 365 days)

Press

to return to SYSTEM mode.

autotune Function & Brief Description

autotune Function & Brief Description

autotune 1:

single-seated valves NC
Flap valves NC
Double-seated valves without clock function of valve
plate

autotune 4:

single-seated valves AA
Flap valves AA

autotune 2:

single-seated valves NO
Flap valves NO

autotune 5:

single-seated valves NC with three-position actuator
Flap valves NC with three-position actuator

autotune 3:

Double-seated valves with clock function of valve plate

autotune 6:

(Reserved function)

english