So litherm co mpact – SEIFERT Control Cabinet Air Conditioner KG 4310-230V Benutzerhandbuch

Seite 2

Advertising
background image

So

liTherm Co

mPact

43040XXX

43041XXX

43050XXX

43080XXX

43100XXX

43150XXX

Abmessungen

/ D
imensions

Gewicht

– W
eight

(Kg)

27.7

27.7

30

39.7

Schutzart

innen/aussen

/

Protection

rating

int. /ext.

Kühlleistung / Cooling

performance

(D

IN
3168)

ltemittel

/

Refriger

ant

Ma
x.

Betriebsdruck

/

Max. working

pressure

Nennspannung /

Netzf

requenz

/ V
oltage /

Frequency

230V

50/60Hz

120V

60Hz

230V

50/60Hz

120V

60Hz

400V

2~

460V

2~

230V

50/60Hz

120V

60Hz

400V

2~

460V

2~

230V

50/60Hz

120V

60Hz

400V

2~

460V

2~

230V

50/60Hz

120V

60Hz

400V

2~

460V

2~

Nennstrom

/

Rated

current

(A)

2.8

5.4

2.5

5.3

1.6

1.4

3.8

6.4

2.4

2.1

3.2

6.7

2

1.8

5.1

9.6

2.6

2.9

Ma
x.

Anlauf

strom

(A)
Max.

star
t-up
current (A)

6.1

12.5

9.8

19.1

4.3

4.3

10.1

20.5

4.5

4.5

15.9

30.2

5.1

5.1

21.2

39.4

5.3

5.3

Sicherung

Fuse

rating (T)

6

A

10
A

6

A

10
A

2x3.6

A

2x3.6

A

6 A

16
A

2x3.6

A

2x3.6

A

10
A

16 A

2x3.6

A

2x3.6

A

10 A

16 A

2x6

A

2x6

A

Nennleistung

(W)

Power consumption

(W)

335

275

370

440

410

410

410

540

450

450

550

700

600

700

800

880

880

1,000

Umgebungskreislauf

/ Ambient

air
circuit

Schr

ankkreislauf /

Cabinet air

circuit

Zertif
izierung

/ Certif

ications

R134a

PS35

/

PO30

bar

410

m

3

/h

300

m

3

/h

CE

43083XXX

650

x

315

x

260

mm

33.7

IP 54 / IP 24

750 W

(L35L35)

CE

43053XXX

650

x

315 x 260

mm

33.7

IP 54 /

IP 24

550 W (L35L35)

R134a

PS35 /

PO30

bar

410

m

3

/h

300 m

3

/h

CE

PS35 /

PO30

bar

Elektrische Anschlu

ssdat

en / Elect

rical data

Max. Luftvolumenst

ro

m / Air vo

lume flow

90
m

3

/h

115

m

3

/h

500

x

280 x 200

mm

27.7

IP

54
/

IP

24

320 W

(L35L35)

R134a

43103XXX

43153XXX

PS35

/

PO30

bar

R134a

IP

54
/

IP

24

IP

54
/

IP

24

650

x

315

x

260

mm

36

47.7

980

x

395

x

260

mm

1 kW (L35L35)

1.5 kW (L35L35)

R134a

470 m

3

/h

410 m

3

/h

300 m

3

/h

PS35

/ PO30 bar

CE

CE

600

m

3

/h

Controller

The unit is equipped with a temperature controller which regulates the function of

the refrigeration cycle. On normal working condition the display shows the tempera-

ture inside the enclosure. The controller “set point” for the interior of the enclosure

(parameter St) is set at 35

o

C from factory and can be adjusted between +20

o

C and

+50

o

C.

The High temperature alarm (parameter AH) is preset at 55

o

C.

The High Temperature Alarm relay is delivered as “normally closed” (H1=1). If you

need to change it to “normally open”, please modify value of parameter H1 (H1=2).

To modify controller parameters:

1. Press the SET button for more than 3 sec. (if there are active alarms, mute the buzz-

er). The display shows the parameter code ‘PS’ (password);

2. Only for parameters requiring password: Press the SET button to access the pass-

word setting, use the UP and DOWN buttons to scroll the numbers until displaying,

“22” (default password to access the parameters), press the SET button to confirm the

password

3. Use the UP and DOWN buttons to scroll the parameters. The LED

corresponding to the category of parameters will be on

4. Press SET to display the value associated with the parameter

5. Increase or decrease the value using the UP or DOWN button respectively

6. Press SET to temporarily save the new value

7. Press the SET button for more than 3 sec. to permanently save the new parameters

and exit the parameter setting procedure.

If no button is pressed for 60 sec. all changes made to the parameters, temporarily

saved in the RAM, will be cancelled and the previous settings restored. The cooling

unit manufacturer is in no way liable for any alterations the customer may make to

the factory set parameters, unless the manufacturer has authorized the customer in

writing to change them.

T

his manual is intended as quick reference for controller, for a full controller man-

ual or if you need to restore the factory parameters please logon to our website

www.seifertsystems.com to download the full manual or to locate your nearest

servicing office.

Door Switch:

The unit can be switched on and off via a door contact switch (terminals T1 & T2).

When delivered the door contact terminals are bridged on the female connector. To

connect the door contact switch remove the bridge and connect door contact switch.

The contact must be closed when the cabinet door is closed.

EN

Steuerung

Das Kühlgerät ist mit einer Temperatursteuerung ausgestattet welche die Funktionen

des Kältekreislaufs regelt. Der Steuerungssollwert für die Schaltschrankinnentem-

peratur (Parameter St) ist werkseitg auf +35

o

C voreingestellt, kann aber wahlweise

auf Werte zwischen +20

o

C und +50

o

C geändert werden. Der Alarmwert für zu hohe

Temperatur (Parameter AH) ist werkseitig auf 55

o

C eingestellt.

Das Relais für den Alarm zu hohe Temperatur ist werkseitig auf “ normal geschlossen”

(H1=1) eingestellt. Wenn Sie auf “normal offen” wechseln möchten, ändern Sie bitte

H1 auf H1=2.

Zugriff auf die Parameter:

• Die SET-Taste für länger als 3 Sek. gedrückt halten (im Alarmfall den Summer abstel-

len). Auf dem Display erscheint der Code des Parameters “PS” (Passwort).

• Die Parameter mit den UP- und DOWN-Tasten ablaufen. Auf dem Display erscheint

die LED der jeweilgen Parameterkategorie.

• Die SET-Taste drücken, um den zugehörigen Wert anzuzeigen.

• Den Wert mit den UP- und DOWN-Tasten erhöhen oder vermindern.

• Mit SET den neuen Wert vorübergehend speichern und zur Parameterebene zurück-

kehren.

• Das Verfahren für die anderen, zu ändernden Parameter wiederholen.

• Die SET-Taste für länger als 3 Sek. drücken, um die Parameter endgültig zu

speichern und das Änderungsverfahren zu verlassen.

Wird für 60 Sek. keine Taste gedrückt, werden alle Parameteränderungen, die

vorübergehend im RAM gespeichert sind, annulliert und die vorhergehenden Einstel-

lungen werden wiederhergestellt.

Der Hersteller des Kühlgerätes ist in keinem Fall für Änderungen die der Kunde an

den werkseitigen Einstellungen vollzogen hat verantwortlich, es sei denn er hat den

Kunden hierzu vorher schriftlich authorisiert.

Diese Kurzanleitung zum Bedienen der Steuerung dient nur als Referenz. Um das

komplette Handbuch für die Steuerung herunterzuladen, oder die Werkeinstellungen

wiederherzustellen, gehen Sie bitte auf unsere Webseite www.seifertsystems.com

oder kontaktieren Sie einen unserer Servicepartner.

Türschalter:

Das Kühlgerät kann mittels eines Türkontaktes ein- und ausgeschaltet werden

(Klemmen T1 & T2). Werkseitig sind diese Klemmen überbrückt. Um den Türkontakt

anzuschliessen entfernen Sie bitte die Brücke. Der Kontakt muss geschlossen sein

wenn die Türe zu ist.

DE