14

ENGLISH

The welding parameters shown in the tables are only guide values for which
ROTHENBERGER cannot accept any guarantee! The parameters recommended by the pipe
and shaped piece manufacturer must be obtained fort he specific materials.

Table 2: Guide value table for PE-HD pursuant to DVS 2207 T1 (09/2005):

Pipe outer

Heating time Heating time Positioning

Cooling time

holding total

(sec) (min)

diameter

SDR

6

– 7,4 - 11

SDR

17

(mm)

(sec)

(sec)

(sec)

16

5

4

6

2

20

5

4

6

2

25

7

4

10

2

32

8

6

10

4

40

12

6

20

4

50

18

6

20

4

63

24

8

30

6

75

30

18

8

30

6

90

40

26

8

40

6

110

50

36

10

50

8

125

60

46

10

60

8

Table 3: Guide value table for PP pursuant to DVS 2207 T11 (08/2008):

Pipe outer

Heating time Heating time Positioning

Cooling time

holding total

(sec) (min)

diameter

SDR

6

– 7,4 - 11

SDR

17

– 17,6

(mm)

(sec)

(sec)

(sec)

16

5

4

6

2

20

5

4

6

2

25

7

4

10

2

32

8

6

10

4

40

12

6

20

4

50

18

6

20

4

63

24

10

8

30

6

75

30

15

8

30

6

90

40

22

8

40

6

110

50

30

10

50

8

125

60

35

10

60

8

Table 4: Guide value table for PVDF pursuant to DVS 2207 T15 (12/2005):

Pipe outer

min. pipe

Heating time Positioning

Cooling time

holding total

(sec) (min)

diameter

wall thickn.

(mm)

(mm)

(sec)

(sec)

16

1,5

4

4

6

2

20

1,9

6

4

6

2

25

1,9

8

4

6

2

32

2,4

10

4

12

4

40

2,4

12

4

12

4

50

3,0

18

4

12

4

63

3,0

20

6

18

6

75

3,0

22

6

18

6

90

3,0

25

6

18

6

110

3,0

30

6

24

8

Advertising