Positioning

This appliance can be installed in a dry, well ventilated indoor (garage or cellar) also, but

for optimum performance install this appliance at a location where the ambient temper-

ature corresponds to the climate class indicated on the rating plate of the appliance:

Climate class

Ambient temperature

SN

+10°C to + 32°C

N

+16°C to + 32°C

ST

+16°C to + 38°C

T

+16°C to + 43°C

Levelling

When placing the appliance ensure that it

stands level. This can be achieved by two adjust-

able feet at the bottom in front (2). If necessary

adjust the feet by removing the spacer (1).

Location

The appliance should be installed well away

from sources of heat such as radiators, boilers, di-

rect sunlight etc. Ensure that air can circulate

freely around the back of the cabinet.To ensure

best performance, if the appliance is positioned

below an overhanging wall unit, the minimum

distance between the top of the cabinet and the

wall unit must be at least 100 mm . Ideally, how-

ever, the appliance should not be positioned be-

low overhanging wall units. Accurate levelling is

ensured by one or more adjustable feet at the

base of the cabinet. If the cabinet is placed in a

corner and the side with the hinges facing the wall, the distance between the wall and

the cabinet must be at least 10 mm to allow the door to open enough so that the

shelves can be removed.
WARNING!

It must be possible to disconnect the appliance from the mains power supply; the plug

must therefore be easily accessible after installation.

1
2

15mm

15mm

100mm

Installation

13