Operating Instructions Safety Switches Series GP...AS
Status table
Programming
State
D0, D1
D2, D3
Monitor diagnosis
Green
Safety guard closed
Code sequence
If start-up test selected:
yellow flashing on start-up
2-channel
Intermediate state during opening or closing
dependent
of the safety guard.
Half-seq.
00
During opening: yellow flashing
Synchronization time
Switch S1 (internal) open
During closing: red
3 s
Intermediate state during opening or closing
After expiration of the synchronization time:
of the safety guard.
00
Half-seq.
yellow flashing
Switch S2 (internal) open
Safety guard open
00
00
Red
Address 0 or communication disrupted
–