2 pin assignment, Data transfer – EUCHNER HBAS 094594 Benutzerhandbuch

Seite 44

Advertising
background image

EUCHNER

Hand-Held Pendant Station

HBAS-094594

095640-02-02/06

Subject to technical modifications

Page 4 / 40

1.2 Pin assignment

Enabling
switch left

a
b

a

b

Contacts

open

closed

Trigger point

1

2

3

E1
E2

E1
E2

1

3

2

4

3

4

3

E1

E2

S2

16

18

19

X3:3

X3:2

X3:4

X3:1

Emergency-stop

1

2

1

2

S1

11

14

13

Power

supply

Micro-

controller

Display

+24 V

0 V

X1:2

X1:3

Shield

4

3

15

1

7

9

RX

RX

TX

X1:6

X1:4

X1:1

X1:5

TX

Communication

Interface RS422

10

8

S1-b1

S1-a1

S1-b2

S1-a2

A

A

X2:5

X2:6

Pulse generator

RS422

POWER

STATUS

Keyboard

Program-

memory

FLASH

Display-

memory

RAM

2

5

B

X2:1

6

B

X2:4

12

X2:3

X2:2

17

screen electrically connected
to the plug housing

WH

GYPK

GN

YE

BNGN

RDBU

WHYE

YEBN

BU

VT

RD

BK

BN

GNWH

GYWH

GY

PK

BNGY

BNPK

BUWH

BNBU

RDWH

WHPK

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

0,14²

not connected:

Interface

Advertising