Electrical installation

Adapter board assignment

5

l

µ

33

LDCDS−CSB7 DE/EN 1.0

5.2

Adapter board assignment

The adapter board is located within the mounting frame of the Command Station. The
scope of supply includes four connector plugs that are plugged on the basic housings of the
adapter board in position X1 to X4.

CSB 7

CSB−006

Description

Type of connection

Cable type

Connections for wiring the
control/display elements of
the control desk

10 pole Phoenix Combicon

socket with spring pressure

connection, type FK−MC

0.5/10−ST−2.5

Flexible due to wire end

ferrule, conductor

cross−section 0.14 ... 0.5 mm

2

CSB−008

Contact

Assignment

X1

X2

X3

x4

1

Key voltage S1 ... S7

(e. g. +24 V)

LED−GND (LED 1 ... 7)

Key voltage S1 ... S7

(e. g. +24 V)

N.C.

2

S 1.1

LED D1 anode

S 1.2

N.C.

3

S 2.1

LED D2 anode

S 2.2

N.C.

4

S 3.1

LED D3 anode

S 3.2

N.C.

5

S 4.1

LED D4 anode

S 4.2

N.C.

6

S 5.1

LED D5 anode

S 5.2

N.C.

7

S 6.1

LED D6 anode

S 6.2

N.C.

8

S 7.1

LED D7 anode

S 7.2

N.C.

9

Emergency stop 1.1

Emergency stop 2.1

Potential I: S1/S5

Potential III: S3/S7

10

Emergency stop 1.2

Emergency stop 2.2

Potential II: S2/S6

Potential IV: S4