Installation, Important notes, Electrical data – Lenze EL 1xx MPI Benutzerhandbuch

Seite 29: Mechanical data

Advertising
background image

Installation

Important notes

LDCDS−EL100MA DE/EN 2.2

29

l

H1inst−MPI_Tab

4

Installation

Important notes

ƒ Before working on the HMI, the supply connector must be unplugged. This is

particularly important before opening the enclosure and connecting/removing
connectors.

ƒ The voltage input is not internally fused and may be destroyed if the input voltage is

too high. Observe the maximally permissible input voltage and professionally fuse
the device on the input side against voltage fluctuations and peaks.

ƒ During installation, see that the maximally permissible ambient temperature is not

exceeded. Corresponding measures for active or passive cooling must be taken if
required.

ƒ The HMI is a device of class A and can cause radio interference in residential areas. In

this case, the operator may have to take special measures. Any costs arising from
these measures have to be paid by the operator.

ƒ In the case of an error, send the HMI to the manufacturer. The address is provided on

the return envelope of this documentation. Please use the original packaging if you
return the HMI!

Electrical data

Supply

Type EL xxx

105m

105

106

108

110

110s

Voltage

[V]

DC 24 (+18 ... 30)

Current at 24 V

[A]

0.25

0.3

0.3

0.5

0.5

Power at 24 V

[W]

6.0

7.2

7.2

12.0

12.0

Mechanical data

Design and weight

Type EL xxx

105m

105

106

108

110

110s

Front

Aluminium with polyester film to DIN 42115

Cover

Sheet steel, galvanised

Weight

[kg]

1.1

1.1

1.2

1.5

2.0

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: