5electrical installation – Lenze MC−ISI Benutzerhandbuch

Seite 30

Advertising
background image

5

Electrical installation

MA_MCISI DE/EN 3.0

30

l

H1_E_INST−HIN_Verdrahtung_RS422/485

Configuration

DIP switch for setting the mode:

DIP switch

Description

1 2 3 4

ON

Pos. 1 = ON: RS485 mode
Pos. 2 = ON: RS422 mode
Pos. 3 = ON/OFF: four−wire conductor/two−wire conductor (only relevant
for RS485 mode)
Pos. 4 = ON/OFF: echo function activated/deactivated (only relevant for
RS485 mode + two−wire conductor)

MC−ISI_004

Set the mode:

Mode

DIP switch setting

RS485 mode, two−wire conductor, deactivated echo function
(default)
RS485 mode, two−wire conductor, activated echo function
RS485 mode, four−wire conductor
RS422

Pos. 1 = ON
Pos. 1+4 = ON
Pos. 1+3 = ON
Pos. 2 = ON

)

Note!

ƒ

If switch 1 = ON (RS485), switch 2 must be set to OFF;
if switch 2 = ON (RS422), switch 1 must be set to OFF.

ƒ

The echo function monitors the RS485 bus for collisions.

Advertising