Resin change, Nlite, Hydropower™ di – Unger nLite HydroPower DI Benutzerhandbuch

Seite 12: 3 resin change - loose resin

Advertising
background image

Quality Tools for Smart Cleaning

www.ungerglobal.com

I

J

K

L

M

12

5.3 Resin Change - loose resin

NOTE: Pay attention to not overfill the vessel. Only use new, saturated wet resin. Never use

dry resin as this will expand a lot and can damage the system.

1. SHUT OFF TAP WATER SUPPLY VALVE

a. Shut off tap water supply and open pole tubing discharge line.

b. Disconnect feeding tap water line and allow system to drain.

2. REMOVE TOP CAP ASSEMBLY:

a. Press yellow FastLock™ Opening lever (3) to get pressure out of the vessel,

(fig. I) fix the base unit with your feet, press the top cap

slightly down and use a counter-clockwise 1/8 turn to release top cap

assembly; remove and set aside (fig. J).

b. Empty the resin out of the vessel by tipping it over or by using a small

shovel; discard according to local regulations.

3. REPLACE RESIN

a. Fill with new resin out of a bag (fig. K). Pay attention to not overfill the vessel.

Only use new, saturated wet resin. Never use dry resin as this will expand

a lot and can damage the system.

b. Only fill with the following quantities into the vessel:

Small system: max. 6,25l wet resin

Medium system: max.12,5l wet resin

Big system: max. 25l wet resin

1 cm from the top of the resin to the ledge of the vessel

must stay unfilled to prevent damage.

c. Inspect system head assembly: O-ring and FloWater™ distribution

filter are in good condition. Re-coat O-ring with silicone lubricant only.

Pay attention that no resin beads are in the screwing mechanism.

d. Re-install DI System head assembly, press it slightly, then turn it 1/8

clockwise while fixing the base unit with your feet.

e. System is ready to be operated.

4. RECONNECT WATERFED POLE TUBING (fig. L)

a. Turn “ON“ water supply at tap.

b. Inspect system as it pressurizes.

c. Keep discharge line open and hold down yellow lever (3) to remove

trapped air from system.

5. TEST SYSTEM TDS (fig. M)

ATTENTION: Spilled resin is a slipping hazard. Clean up spilled resin immediately.

nlite

®

Hydropower™ dI

Resin Change

Advertising