9 technical data, 1 electrical data, 2 mechanical data – Baumer HEAG 176 Benutzerhandbuch

Seite 13: Technical data, Electrical data, Mechanical data

Advertising
background image

MB006

heag171-176_mb (13A1)

10

9.1

Electrical data

Transmission length: ≤300 m

HEAG 171

Voltage supply:

9...26 VDC

5 VDC ±5 %

Consumption:

≤200 mA

Inputs:

4 x TTL

Input signals:

K1, K2, K3, K4 + inv.

Outputs:

4 x fiber optic

Output signals:

Fiber optic 1, 2, 3, 4

HEAG 172

Voltage supply:

9...26 VDC

Consumption:

≤200 mA

Inputs:

4 x HTL

Input signals:

K1, K2, K3, K4 + inv.

Outputs:

4 x fiber optic

Output signals:

Fiber optic 1, 2, 3, 4

HEAG 173

Voltage supply:

5 VDC ±5 %

Consumption:

≤60 mA

Inputs:

3 x fiber optic

Input signals:

Fiber optic 1, 2, 3

Outputs:

3 x TTL

Output signals:

K1, K2, K3 + inv.

HEAG 174

Voltage supply:

9...26 VDC

Consumption:

≤60 mA

Inputs:

3 x fiber optic

Input signals:

Fiber optic 1, 2, 3

Outputs:

3 x HTL

Output signals:

K1, K2, K3 + inv.

HEAG 175

Voltage supply:

9...26 VDC

5 VDC ±5 %

Consumption:

≤200 mA

Technical data

9

Inputs:

3 x TTL

Input signals:

K1, K2, K3 + inv.

Outputs:

3 x fiber optic

Output signals:

Fiber optic 1, 2, 3

HEAG 176

Voltage supply:

9...26 VDC

Consumption:

≤200 mA

Inputs:

3 x HTL

Input signals:

K1, K2, K3 + inv.

Outputs:

3 x fiber optic

Output signals:

Fiber optic 1, 2, 3

9.2

Mechanical data

HEAG 171, HEAG 172

Dimensions

W x H x L:

122 x 122 x 80 mm

Protection:

IP 65 IEC 60529

Operating

temperature:

-20...+70 °C

(without dew)

Connection:

3x cable gland

M20x1,5

4x cable gland

M16x1,5

HEAG 173, HEAG 174, HEAG 175,

HEAG 176

Dimensions

W x H x L:

50 x 75 x 55 mm

Protection:

IP 20 IEC 60529

Operating

temperature:

-20...+50 °C

(without dew)

Connection:

3x screw terminal

connector

Connector (VL, ST

or SMA)

9

Technical data

Advertising