9. Programming plan

Zl 11-16

Status for Line 1-6

0 * Parameter can be changed
1

Clearing and/or input disabled

2

Parameter is skipped

Line 23

Input logic for control inputs

0 * Operating threshold 6 V
1

Operating threshold 3 V

Line 24

Decimal point for tachometer F

0 * No decimal point
1

00000.0

2

0000.00

3

000.000

Line 26

Offset

0 * No offset
1

Offset 2V/4mA without monitoring < 2V

2

Offset 2V/4mA with monitoring < 2V

Line 28

Update time (repeated display)

0

0,1 s

1

0,5 s

2 * 1 s
3

2 s

4

3 s

5

5 s

6

10 s

7

20 s

8

30 s

9

60 s

Line 31

Function of control input 1

0 * Hold
1

Reset maximum-value memory

2

Programming disable

3

Keylock

4

Print

Line 32

Function of control input 2

0

Hold

1 * Reset maximum-value memory
2

Programming disable

3

Keylock

4

Print

Line 33

Allotment output P1

0 * Top limit value tachometer
1

Bottom limit value tachometer

Line 34

Allotment output P2

0 * Top limit value tachometer
1

Bottom limit value tachometer

Line 35

Output logic for relay outputs

0 * Both outputs as normally open
1

Out 1 normally closed, Out 2 normally open

2

Out 1 normally open, Out 2 normally closed

3

Both outputs as normally closed

Line 39

Hold delay time

0 * No delay
1

Delay 1 s

:

4

Delay 9 s

Line 40

Code setting

0000 * Code not active
:

9999

Line 51

Baud rate

0 * 4800 Baud
1

2400 Baud

2

1200 Baud

3

600 Baud

Line 52

Parity

0 * Even
1

Odd

2

No

Line 53

Stop bits

0 * 1 stop bit
1

2 stop bits

Line 54

Device address

00 * Minimum value
:

99

Maximum value

Line 55

Allotment output value via interface

0 * F
1

SZ

Line 56

RS422: Control connections TxD+,TxD-

0 * switched in sense of transmission for

transmission, in sense of reception for
reception

1

Always in sense of transmission