8 technical data, 1 technical data - electrical ratings, 3 technical data - electrical ratings (sinewave) – Baumer MHGE 100 Benutzerhandbuch

Seite 26: Technical data, Technical data - electrical ratings, Technical data - electrical ratings (square-wave), Technical data - electrical ratings (sinewave)

Advertising
background image

23

Baumer_MHGE100-T2_II_DE-EN (14A3)

MB200T2 - 11121631

8

Technical data

8

Technical data

8.1

Technical data - electrical ratings

Interference immunity:

EN 61000-6-2:2005

Emitted interference:

EN 61000-6-3:2007/A1:2011

Approvals:

CE, RoHS, Option: DNV approval

8.2

Technical data - electrical ratings (square-wave)

Voltage supply (Signals):

RN...C: 4,75...30 VDC (TTL/RS422)

TN...C: 5 VDC ±5 %

(TTL/RS422)

HN...C: 10...30 VDC

(HTL)

UN...C: 5...30 VDC

(TTL/HTL)*

Consumption w/o load:

≤70 mA

Pulses per revolution:

64...4096 (As ordered)

Phase shift:

90° ±10°

Scan ratio:

40...60 %

Reference signal:

Zero pulse, width 90°

Sensing method:

Magnetic

Output frequency:

≤300 kHz

Output signals:

A+, B+, R+, A-, B-, R-

Output stages:

HTL

TTL/RS422

(As ordered)

8.3

Technical data - electrical ratings (sinewave)

Voltage supply (Signals):

SN...C: 5 VDC (SinCos)

Consumption w/o load:

≤70 mA

Sinewave cycles per turn:

64

Phase shift:

90° ±5

Reference signal:

Zero pulse, width 90°

Sensing method:

Magnetic

Output signals:

A+, B+, R+, A-, B-, R-

Output stage:

SinCos 1 Vpp

Difference of SinCos amplitude:

≤20 mV

Harmonics typ.:

-40 dB

DC offset:

≤20 mV

* At +UB = 5 VDC: TTL/RS422; At +UB = 10...30 VDC: HTL