Baumer BA OADM20x24 Benutzerhandbuch

Seite 26

Advertising
background image

BA_OADM20x24.doc

26/39

Baumer

05.12.12

Frauenfeld, Switzerland

Ambient light:
Be careful that no strong light source faces the receiving field.













Several sensors without mutual optical interferences:
Several sensors, when mounted next to the other, can affect each other. When mounting a sensor, be aware
that no laser spot from another sensor is in the receiving field.
When mounted side by side (as shown in the picture in the middle), sensing distances up to 600 mm can be
achieved..

If it is not possible to mount the sensors the correct way, use the sync input and choose the asynchronous
function.

Messbereich

Messbereich

Gegenseitige
Beeinflussung

Advertising