9 technical data, 1 allgemeine daten, Technical data – Baumer GT 5 Benutzerhandbuch

Seite 18: Allgemeine daten

Advertising
background image

15

gt5_mb (12A1)

MB021

9

Technical data

9.1

Allgemeine Daten

Performance:

0.075 W (speed >5,000 rpm)

Calibration tolerance:

±5%

Linearity tolerance:

≤0.15%

Reversal tolerance:

≤0.1%

Superimposed ripple:

≤0.7% peak-peak

(for τ

RC

= 0.3 ms)

≤0.35% rms

Temperature coefficient:

±0.005%/K (idle)

Armature-circuit time-constant (τ

A

):

<4.5 µs

Torque:

0.3 Ncm

Rotor moment of inertia:

0.05 kgcm

2

Permissible armature displacement:

±0.5 mm axial

±0.1 mm radial

Vibration resistance:

100 m/s

2

≈ 10 g

IEC 60068-2-6: 2007

(10-2,000 Hz)

Shock resistance:

1,000 m/s

2

≈ 100 g

IEC 60068-2-27: 2008

(6 ms)

Operating temperature:

-30°C...+130°C

Isolation class:

B

Protection IEC 60529:

IP 00 with cover

IP 44 with complete cover

IP 54 with complete cover and cable gland

Climatic tests:

IEC 60068-2-3, Ca (dump heat, constant)

Weight approx.:

150 g

EMC according to:

EN 61000-6-2: 2005 (interference immunity)

EN 61000-6-4: 2007 (emitted interference)

9

Technical data

Advertising