Technical data

* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution

8

Technical data

8.1

Technical data - electrical ratings

Interference immunity:

EN 61000-6-2:2005

Emitted interference:

EN 61000-6-3:2007/A1:2011

Approval: CE

8.2

Technical data - electrical ratings (encoder)

Voltage supply:

9...30 VDC* (HTL-P, TTL - Version R)

5 VDC ±5 % (TTL)

Consumption w/o load:

≤100 mA

Pulses per revolution:

300...5000 (As ordered)

Phase shift:

90° ±20°

Scan ratio:

40...60 %

Reference signal:

Zero pulse, width 90°

Output frequency:

≤120 kHz

≤300 kHz option

Output signals:

K1, K2, K0 + inverted

Error output (only EMS)

Output stages:

HTL-P (power linedriver)

TTL/RS422

(As ordered)

Sensing method:

Optical

8.3

Technical data - electrical ratings (centrifugal switch)

Switching accuracy:

±4 % (Δn = 2 rpm/s)

≤ +20 % (Δn = 1500 rpm/s)

Switching deviation cw-ccw rotation:

≤3 %

Switching hysteresis:

~40 % of switching speed

Switching outputs:

1 output, speed control

Output switching capacity:

≤6 A / 230 VAC

≤1 A / 125 VDC

Minimum switching current:

50 mA