10

11

12

14

15

16

13

9

Danger

Warnings of possible danger.

General instructions

Information on appropriate product handling.

General remarks

Additional information

The installation instruction is supplementary to already

existing documentation (e.g. catalog, data sheet, manual).

It is imperative to read the manual carefully prior to star-

ting the device.

Appropriate use

- The encoder is a precision measuring device. It is ex-

plicitly designed for registration of angular positions

and revolutions as well as evaluation and supply of

measuring values as electric output signals for the sub-

sequently connected device. The encoder must not be

used for any other purpose.

Start up

- Installation and assembly of the encoder only by electri-

cally skilled and qualified personnel.

- Consider also the operation manual of the machine

manufacturer.

Safety instructions

- All electrical connections are to be revised prior to star-

ting the system.

- Incorrect assembly and electrical connections or any

other inappropriate work at encoder and system may

lead to malfunction or failure of the encoder.

- Any risk of personal injury, damage of the system or

company equipment due to failure or malfunction of the

encoder has to be eliminated by corresponding safety

measures.

- Do not operate encoder beyond the limit values stated

in the data sheet.

Any disregard may lead to malfunctions, material damage

and personal injury.

Fixing bore

Eccentric

fixing



Disposal

Encoder components are to be disposed of according to

the regulations prevailing in the respective country.

Transport and storing

- In original packing only.

- Do not drop or expose encoder to major shocks.

Assembly

- Avoid punches or shocks on case and shaft.

- Avoid case distortion.

- Do not use any rigid links between encoder shaft and

drive shaft.

- Do not open or modify encoder in any mechanical way.

Shaft, bearing, glass disc or electronic componen-

ts might be damaged and a secure operation is no

longer guaranteed.

Mechanical assembly

- Mount encoder using three screws using the three

fixing bores of the flange. Consider the depth and dia-

meter of the thread.

- Alternative mounting in any angular position is possible

by means of three eccentric fixings (accessories).

- Use appropriate coupling to link drive shaft and encoder

shaft. For appropriate links please refer to accessories.

The ends of the shafts must not touch each

other. Any displacements due to temperature or

mechanical tolerances have to be equalized by the

coupling. Mind the maximum permitted axial or

radial shaft load. Tighten fixing screws firmly.

Electrical installation

- Do not modify encoder in any electrical way and carry

out any wiring work under power supply.

- Any electrical connection and plugging-on whilst under

power supply is not permitted.

- A separate encoder supply has to be provided with con-

sumers with high interference emission.

- Encoder case and supply cable have to be completely

screened.

- Installation of the whole system has to be according

to EMC standards. Installation environment as well as

wiring have an impact on the encoder’s EMC. Encoder

and supplying lines are to be in separated locations or

remote from lines with high interference emission (fre-

quency transformers, protections, etc.).

- Ground (PE) encoder by using screened cables. The brai-

ded shield has to be connected to cable gland or plug.

Grounding (PE) on both sides is recommended.Ground

the case by the mechanical assembly, if latter is electri-

cally isolated a second connection has to be provided.

Ground cable screen by the subsequently connected

devices. In case of ground loop problems at least groun-

ding on one side is imperative.

Any disregard may lead to malfunctions, material damage

and personal injury.

Electrical connection

Any outputs not used must not be connected. Unused

cable cores have to be isolated. Max. bending radius of

cables 90 mm. After the reset process the zero input

should be grounded (GND) externally for better protection

against interferences.

Connection – M23 connector

Whilst not connected, the M23 connector is always to be

sealed by the plastic cover provided by the manufacturer

upon delivery. Appropriate mating connectors available as

spare part or with different cable length, please refer to

accessories. In case of customer-specific length use on-

ly screened cable and connectors corresponding to EMC

standards. Consider the wiring instructions of the respec-

tive supplier.

- Press mating connector softly onto the M23 connector.

- Turn mating connector carefully until the code-mark is

interlocking the corresponding space provided by the

M23 connector.

- Insert bushing completely and tighten the nut as far as

possible.

An optimized connection between encoder case and the

braided shield of the connection cable is only achieved by

the braided shield being placed generously onto the con-

nector and the nut being secured firmly

Connector dimensions

1

2

3

4

5

6

7

8

9

10

12

11

Terminal assignment
Connector Core colour

Assignment

Pin 1

brown

UB

Pin 2

black

GND

Pin 3

blue

Clock+

Pin 4

beige

Data+

Pin 5

green

Zero

Pin 6

yellow

Data-

Pin 7

violet

Clock-

Pin 8

brown/yellow DATAVALID

Pin 9

pink

UP/DOWN

Pin 10

black/yellow

DATAVALID MT

Pin 11

Pin 12

with incremental tracks
Connector Core colour

Assignment

Pin 1

brown

UB

Pin 2

white

GND

Pin 3

blue

Clock+

Pin 4

green

Data+

Pin 5

grey

Zero

Pin 6

yellow

Data-

Pin 7

red

Clock-

Pin 8

red/blue

Track B inv.

Pin 9

pink

UP/DOWN

Pin 10

violet

Track A inv.

Pin 11

black

Track A

Pin 12

grey/pink

Track B

Please use cores twisted in pairs (for example clock+/

clock-) for extension cables of more than 10 m length.

GM400, GM401
GE404
GBM2W, GXL2W
Absolute Encoder – SSI

9-16

Assembly Instructions

GB

Dimensions

Clamping flange

Synchro flange

58

59

3

M4x7 (3x120°)

42 ±0.1

3

9

10

4

ш5

2

5.

5

ш6f8

ø5

0h

7

ш5

8

9

ш10h6

ø36f8

ш53

ш58

15

20

10

46

11

.5

3

3

9

ш10h6

ø36f8

ш53

ш58

15

20

10

46

16

3

3

9

ш10h6

ø36f8

ш53

ш58

15

20

10

46

M3x7 (3x120°)

48

±0.1

13

59

17

3

3

16

9

ø10h6

ø36f8

ш53

ш58

15

20

10

46

M3x7 (3x120°)

48

±0.1

17

3

3

with sine/cosine
Connector Core colour

Assignment

Pin 1

brown

UB

Pin 2

white

GND

Pin 3

blue

Clock+

Pin 4

green

Data+

Pin 5

grey

Zero

Pin 6

yellow

Data-

Pin 7

red

Clock-

Pin 8

red/blue

Cosine

Pin 9

pink

UP/DOWN

Pin 10

violet

Sine

Pin 11

black

Sine

Pin 12

grey/pink

Cosine

Advertising