5.2 Selecting Display (only DDBF 2-SC)
ENTER
ESC
PROG
DISPLAY
CH A
DISPLAY
CH B
DISPLAY
SUM
PARA 1
DISPLAY CH A
DISPLAY
CH A+B
“Enter”
To switch from PARA1
into display selection
“Esc”
Back to PARA1 without
saving the setting
“Prog.”
Back to PARA1 saving
the selected display
setting
To select display setting
5.3 Changing polarity
ENTER
CHANGE POLARITY
OFF
CHANGE POLARITY
ON
ESC
PROG
PARA 2
CHANGE POL OFF
Change polarity OFF
tension
pos.
compression
neg.
Change polarity ON
tension
neg.
compression
pos.
“Enter”
To switch from PARA2
into the polarity change
function
“Esc”
Back to PARA2 without
saving the setting
“Prog.”
Back to PARA2 saving
the selected setting
To activate or deactivate
polarity change
DDBF_BA_V2_0.doc
36/44
Baumer Electric AG
05.09.07/rut
Frauenfeld, Switzerland
5.4 RESET
ENTER
RESET
DISABLE
RESET
ENABLE
ESC
PROG
PARA 3
RESET NO
RESET ENABLE
All displayed values and
analog outputs are tarred.
RESET DISABLE
Only the PEAK value is
tarred
“Enter”
To switch from PARA3 into
selecting the RESET function
“Esc”
Back to PARA3 without saving
the setting
“Prog.”
Back to PARA3 saving the
selected setting
To activate or deactivate the
RESET function
5.5 Display unit
ENTER
ESC
PROG
CALC Unit
uE
CALC UNIT
kN
CALC UNIT
t
PARA 4
CALC uE
Note:
The device is set to the
µε
unit by default. If the
display in [kN] or [t] is selected, the value is
calculated on the basis of the entered values
(diameter, Young’s modulus). Ensure that the correct
values for Young’s modulus and diameter have been
entered in the menu:
PARA 5
CALC PARA
“Enter”
To switch from PARA4 into display
unit selection
“Esc”
Back to PARA4 without saving the
setting
“Prog.”
Back to PARA4 saving the selected
setting
To select the unit