2 operation in potentially explosive environments, Operation in potentially explosive environments – Baumer EEx HOG 161 Benutzerhandbuch

Seite 7

Advertising
background image

MB044T2 - 11068773

Baumer_EEXHOG161-T2_II_DE-EN (14A1)

4

Operation in potentially explosive environments

2

2

Operation in potentially explosive environments

2.1

The device complies with the

EU standard 94/9/EG for potentionally explosive atmospheres

and with the

IECEx Scheme.

It can be used in accordance with

equipment category 2 G (explosive gas atmosphere).

Equipment category 2 G: - Ex labeling:

II 2 G Ex d e IIC T6 Gb

Ex d e IIC T6 Gb

- Conforms to standard: EN 60079-0:2009 / IEC 60079-0:2011

General defination

EN 60079-1:2007 / IEC 60079-1:2007

Explosion proof enclosure „d“

EN 60079-7:2007 / IEC 60079-7:2006

Increased safety „e“

- Type of protection:

d e

- Temperature class:

T6

- Group of equipment: II

- Explosive gas group: IIC

- Device protection level: Gb

The operation in other explosive atmospheres is

not permissible.

EG design test certificate on demand:

TÜV NORD CERT Nr. TÜV 02 ATEX 1921 X

IECEx TUN 12.0029 X

2.2

In Ex areas the device must only be used within the

ambient temperature range from -20 °C to

+58 °C (IP 56) resp. -20 °C to +66 °C (IP 54).

2.3

Any

UL listing that may be quoted in any other technical documentation does not apply to use in

the Ex area.

2.4

Operation of the device is only permissible when ...

the details on the type label of the device match the on-site conditions for the permissible

Ex area in use (group of equipment, equipment category, zone, temperature class or maxi-

mum surface temperature),

the details on the type label of the device match the electrical supply network,

the device is undamaged (no damage resulting from transport or storage), and

it has been checked that there is no explosive atmosphere, oils, acids, gases, vapors,

radiation etc. present during installation.

2.5

It is not permissible to make any alteration to equipment that is used in potentially explosive envi-

ronments. Repairs may only be carried out by authorized authorities provided by the manufacturer.

Contravention invalidates the EX approval.

2.6

Attend the norm EN 60079-14 / IEC 60079-14 during mount and operation.

The device must be operated in accordance with the stipulations of the installation and

operating instructions. The relevant laws, regulations and standards for the planned ap-

plication must be observed.

Advertising