5technical data, 1 electrical data – Baumer BA DABx AD2T Benutzerhandbuch

Seite 19

Advertising
background image

DABx_AD2T_BA_V1_0m.doc

19/20

Baumer Electric AG

01.04.09/rut

Frauenfeld, Switzerland

5

Technical data

5.1

Electrical data

DABU AD2T-FB

DABI AD2T-FB

DABU AD2T-2Q

Allgemein

Supply voltage

18 – 33 VDC

14 – 33 VDC

18 – 33 VDC

Current draw

< 60mA

< 40mA @ 24VDC

< 90mA

< 70mA @ 24VDC

< 60mA

< 40mA @ 24VDC

Reset input active

inactive

5 – 33 VDC < 2mA

< 1 VDC

Heating time of the measuring

chain

Min. 10 min

Min. 10 min

Input signal

Bridge excitation

Ca. 7VDC

S/G bridge resistance

35Ohm

Analog output

Characteristic curve deviation

<

±

0.2 % FSR

<

±

0.5 % FSR @ 0.25mV/V

<

±

0.25 % FSR @ 0.50mV/V

<

±

0.2 % FSR @ 1.00mV/V

<

±

0.2 % FSR @ 2.00mV/V

<

±

0.2 % FSR

Reset

Tare range (Reset)

±

6 mV / V

Frequency range(-3dB)

1’000Hz

Signal polarity

bipolar

unipolar

bipolar

Noise

(0..5kHz)

0.25 < 15mVpp

0.50 < 7.5mVpp

1.00 < 5mVpp

2.00 < 5mVpp

(0..5kHz)

0250 < 15mVpp

0350 < 12mVpp

0500 < 7.5mVpp

1000 < 5mVpp

For further information please see the data sheet on

www.baumerelectric.com

.