Electrical data

PSEN me2

PSEN me2.1

PSEN me3

PSEN me3.01
PSEN me3.02

PSEN me3.1

PSEN me3.11

PSEN me3.2

PSEN me3.21

Switching function

1 NC (Y)

1 NO/1 NC (Zb)

2 NC (Zb)

1 NO/2 NC (Zb)

Switch symbol

Rated insulation voltage

U

i

250 V AC

250 V AC

250 V AC

400 V AC

Conventional thermal current

I

the

5 A

10 A

10 A

5 A

Utilization category
acc. IEC/EN 60947-5-1

AC-15, U

e

/I

e

240 V/1,5 A

AC-15, U

e

/I

e

240 V/3 A

AC-15, U

e

/I

e

240 V/3 A

AC-15, U

e

/I

e

240 V/1,5 A

Type of short-circuit protection

6 A gL/gG

10 A gL/gG

6 A gL/gG

6 A gL/gG

Melting fuse acc. IEC/EN 60947-5-1, annex K

Forced disconnection (N.C.)

IEC/EN 60947-5-1

Degree of protection

II, protective insulation

Mechanical data

Enclosure

Thermoplastic, glass fiber reinforced (UL94-V0)

Cover

Thermoplastic, glass fiber reinforced (UL94-V0)

Ambient air temperature

-30°C to +80°C, -22°F to +176°F

Cable entry

PSEN me2, PSEN me2.1

3 x M16x1,5

PSEN me3, PSEN me3.01, PSEN me3.02

3 x M20x1,5

PSEN me3.1, PSEN me3.11

3 x M20x1,5

PSEN me3.2, PSEN me3.21

2 x M20x1,5

Protection class

IP65 acc. EN 60529; DIN VDE 0470 T1

Weight

PSEN me2 ≈ 0,1 kg

PSEN me3 ≈ 0,13 kg

Actuating device

Actuator

Separate actuator (St stainless)

Actuating radius

2AS

≥ 150 mm

2AR

≥ 50 mm

Actuating speed

≤ 0,2

m

/

s

Extraction force

Standard

10N

PSEN me3.02

30N

PSEN me2.1, PSEN me3.01,
PSEN me3.11, PSEN me3.21

100N

Mechanical life

1 x 10

6

switching cycles

1 x 10

5

switching cycles (extended actuation force)

Switching frequency

≤ 30/minute

Standards

VDE 0660 T100, DIN EN 60947-1, IEC 60947-1

VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1

EU-Conformity

Approvals

TÜV Rheinland, Type Approved

C

CSA

US

A300 for PSEN me3, PSEN me3.01,

PSEN me3.02, PSEN me3.1, PSEN me3.11

C

CSA

US

B300 for PSEN me2,

PSEN me2.1, PSEN me3.2, PSEN me3.21

Date of issue: 15.04.2014 / Page 10 of 12

1003287-2EN-03 / Document: 0800000423 / Version: 3 / 2220-14