4 reception data, Add-2, Reception conditions – Yamaha DS55 Benutzerhandbuch

Seite 36

Achtung! Der Text in diesem Dokument wurde automatisch erkannt. Um das ursprüngliche Dokument anzeigen, können Sie den "ursprünglichen Modus" verwenden können.

Advertising
background image

3. Reception Conditions

▼ System real time message

C=7

Foot volume

C=64

Sustain switch

v=0~127
v=0!of f,1271 on

4) PROGRAM CHANGE

STATUS

llOOnnnn

(Cn) n=channel number

PROGRAM No. Oppppppp

p=0~127

PRESET/USER selection is carried out by system PFM parameter
change.
p= 100~127 is received as 0~27.

n=channel number

O = select sw
□ = on/off sw

* MIDI reception is disabled while Auto Performance or Demonstration

are running.

4 Reception Data

4-1 Channel information

★ A maximum of 8 MIDI receive channels are used in the Multi-instrument

Mode.

(1) maximun of 8 MIDI receive channels are used in the

Multi-instrument Mode.

1) NOTE OFF

STATUS

lOOOnnnn

(8n)

n=channel number

NOTE No.

Okkkkkkk

k=0(C-2)~127(G8)

VELOCITY

Ovvvvvvv

V is ignored

NOTE ON/OFF

STATUS

lOOlnnnn

On)

n=channel number

NOTE No.

Okkkkkkk

k=0(C-2)~127(G8)

VELOCITY

Ovvvvvvv

(V^^O)

NOTE ON

00000000

(V = 0)

NOTE OFF

CONTROL CHANGE
STATUS
CONTROL No. ,
CONTROL VALUE

lOllnnnn

Occccccc
Ovvvvvvv

(Bn)

n=channel number

5) PITCH BENDER

STATUS

lllOnnnn

(En)

VALUE(LSB)

Ouuuuuuu

VALUE(MSB)

Ovvvvvvv

Only the MSB data is operative.
Resolution! 7 bits

------ MSB---------

0000 0000

(00)

Minimum value

0100 0000

(40)

Center value

0111 1111

(7F)

Maximum value

4-2 System Information

(1) System Realtime Message

1) ACTIVE SENSING

STATUS

11111110

(FE)

Sensing is begun when this code is received. If no status
byte or data is received within 300 milliseconds, the MIDI

receive buffer is cleared, and all ON notes and the sustain
switch are forced OFF.

(2) System Exclusive Message

1) PARAMETER CHANGE SWITCH REMOTE

STATUS

11110000

(FO)

ID No.

01000011

(43)

SUB STATUS

OOOlssss

(Is) s=Recieve channel

GROUP NUMBER

00100101

(25)

PARAMETER No.

Oppppppp

p=switch number+94(94-127

DATA

Oddddddd

d=0;0FF,d=127;0N

EOX

linoni

(F7)

Received regardless of receive sw/channel.
All panel switches are controlled.
p=127 is power-on reset.

Refer to ’’switch remote” in Chart 1.

The following are received only when the receive channel
matched.

2) PARAMETER CHANGE

STATUS

11110000

ID

No.

01000011

SUB

STATUS

OOOlssss

GROUP NUMBER Oggggghh

PARAMETER No. Oppppppp
DATA

Oddddddd

EOX 11110111

(EO)
(43)
(Is)

(F7)

s=Recieve channel
g=Group number

h=Sub group number

The 5 parameter group numbers and parameter numbers used
are described below.

Type

g

h

P

Number of Data Byte

SYSTEM SET UP

9

1

1-5

1

SYSTEM PFM

4

0

0-95

1

DELAY

9

1

6,7

1

MASTER TUNING

4

0

123

2

BULK BLOCK

9

1

7

1

—- CONTROL NUMBER -------

C=1 Modulation wheel

v=0~127

3) BULK DUMP

Same as for transmission.

Add-2

Advertising