5 installation and startup, 6 technical data – TechniSat TechniLAN 8/8 Passive Benutzerhandbuch

Seite 14

Advertising
background image

14

EN

MONT_TechniLAN_8_8_passiv_DE_EN.doc 04.09.2012 09:02 Seite 14

5 Installation and Startup

Connect the TechniLAN 8/8 passiv to the signal output of the multi-switch. F-to-F quick
connectors (Art. No. 0001/3312) can be used for multi-switches from the series
TechniSwitch 5/8, TechniSystem 5/8 and/or GigaSwitch 9/8 due to the similar grid
system.

The signal outputs of the TechniLAN 8/8passiv are to be connected to the participant
sockets using coaxial cabling.

Replaced the old antenna wall outlets against the TechniLAN participant sockets.

Connect the provided wall power supply. Take care not to exceed the maximum amount of
power allowed by the wall power supply (see section 4.2).

Check, using the LEDs on the TechniLAN participant sockets, as to whether or not the
operating power is being supplied at the socket. The green LEDs must be lit at every socket
(see section 0).

Several seconds later, the Coax-Link LED and the yellow traffic LEDs of the TechniLAN
participant sockets should light up and signal that the coaxial cable network is ready for
operation (see section 0). Network capable terminal devices can now be operated via the
Ethernet sockets of the participant sockets and the TechniLAN 8/8 passiv.


6 Technical Data

TechniLAN 8/8 passiv, Article Number 0000/3638

Number of HF Inputs

8x for satellite, terrestrial and TechniLAN (2...2.150 MHz)

Number of HF Outputs

8x for satellite, terrestrial and TechniLAN (2...2.150 MHz)

Reflexion Dampening

10 dB

Shielding Measurements

According to EN 50083-2 (TechniSelect S)

Network

Coaxial cable network according to HomePlug-AV standard

Max. Data Rate

200 Mbit/s

Satellite Range Dampening

4

2…3 dB

Terrestrial Dampening

4

1…2 dB

Power Supply

Device, participant sockets and distribution technology without power

supply are supplied via the wall power supply.

Wall power supply 230 V / 13 V, 3 A DC, short-circuit and overload

protected.

Power Consumption
(without sockets and
distribution technology)

0 mA

Dimensions: L x B x H (mm),
Weight

217 x 117 x 33, 500 g