Suspended installation

This speaker-system must never be suspended - Danger to Life due to crashing
speaker-systems!

OPERATION

Make sure that the available voltage is not higher than stated on the voltage selector before you connect the
power cord.

Connection with the mains

Connect the device to the mains with the power-plug.

The occupation of the connection-cables is as follows:

Cable

Pin

International

Brown

Live

L

Blue

Neutral

N

Yellow/Green

Earth

The earth has to be connected!

If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.

Switch the device on. After switching on the speaker-system, wait 8 to 10 seconds until you turn the volume-
control in order to avoid speaker-damage.

Caution! Increase the level of each channel only so far that the CLIP-LED lights up shortly. Thus, you avoid
that the output signal is distorted and your speakers are damaged.

When operating the speaker-system, please make sure that the loudspeakers always sound well. When
distorsions can be heard, either the amplifier or the loudspeaker is overloaded. Overloads can quickly lead to
amplifier or speaker damage.

In order to avoid damage, please reduce the volume immediately when distortions can be heard. When
speaker-systems are destroyed by overload, the guarantee becomes void.

Always check the sound pressure level with a meter in order to keep to the threshold.

If you want to switch off the system, switch off the speaker-system first in order to avoid acoustic shocks
on the speakers.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.

The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.

The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not

be corroded.