Replacing the power cable – Parkside PKO 400 B2 Benutzerhandbuch

Seite 13

Advertising
background image

GB/IE

- 13 -

7.8 Setting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar

7.9 Overload cut-out (Fig. 3)
The motor of this equipment is protected against
overload by an overload switch (G). If the rated
current is exceeded, the overload switch (G) will
shut down the equipment. After a short cooling
down period, the equipment can be switched on
again by pressing the overload switch (G).

8. Replacing the power cable

If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel to
avoid danger.

9. Cleaning, maintenance,

storage, ordering spare
parts and transport

ƽ

Important!

Pull out the power plug before doing any
cleaning and maintenance work on the
equipment. Risk of injury from electric
shock!

ƽ

Important!

Wait until the equipment has cooled
down completely! Risk of burns!

ƽ

Important!

Always depressurize the equipment be-
fore carrying out any cleaning and main-
tenance work (see 9.7.1)! Risk of injury!

9.1 Cleaning

Keep the equipment free of dirt and dust as
far as possible. Wipe the equipment with a
clean cloth or blow it down with compressed
air at low pressure.

We recommend that you clean the equipment
immediately after you use it.

Clean the equipment regularly with a damp
cloth and some soft soap. Do not use cleaning
agents or solvents; these may be aggressive
to the plastic parts in the equipment. Ensure
that no water can get into the interior of the
equipment.

You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.

9.2 Maintenance work on the pressure

vessel (Figure 1)

Important! To ensure a long service life of the
pressure vessel (7), drain off the condensed water
by opening the drain valve (9) each time after
using. Release the vessel pressure fi rst (see 9.7.1).
Open the drain screw by turning counter-clock-
wise (looking at the screw from the bottom of the
compressor) so that all the condensed water can
run out of the pressure vessel. Then close the drain
screw again (turn it clockwise). Check the pressure
vessel for signs of rust and damage each time
before using. Do not use the compressor with a
damaged or rusty pressure vessel. If you discover
any damage, then please contact the customer
service workshop.

ƽ

Important!

The condensed water from the pressure
vessel will contain residual oil. Dispose
of the condensed water in an environ-
mentally compatible manner at a suitable
collection point.

Anl_4010166.indb 13

Anl_4010166.indb 13

25.03.13 16:01

25.03.13 16:01

Advertising