Troubleshooting guide, Maintenance schedule – Parkside PSE 2800 B2 Benutzerhandbuch

Seite 13

Advertising
background image

13

GB

Cleaning, maintenance, storage, transport and ... / Disposal and recycling

Troubleshooting guide / Maintenance schedule

Troubleshooting guide

fault

Cause

remedy

Engine does

not start

Automatic oil

cut-out has not

responded

Check oil level,
top up engine oil

Spark plug

fouled

Clean or replace
spark plug
(electrode
spacing 0.6 mm)

No fuel

Refuel / have
the petrol cock
checked

Generator

has too little

or no voltage

Controller or

capacitor

defective

Contact your

dealer

Overcurrent

circuit-breaker

has triggered

Actuate the

circuit-breaker

and reduce the

consumers

Air filter dirty

Clean or replace

the filter

Maintenance schedule

Please adhere to the following maintenance
periods in order to ensure a failure-free operation.

IMPOrTanT! The equipment must be
filled with engine oil and fuel before it
is started.

Before each

use

after an
operating
period of
20 hours

after an
operating
period of
50 hours

after an
operating
period of
100 hours

after an
operating
period of
300 hours

Checking the

engine oil

X

Changing the

engine oil

For the first

time, then every

50 hours

X

Checking the

air filter

X

Change the

filter insert if

necessary

Cleaning the

air filter

X

Cleaning the

petrol filter

X

Visual inspec-

tion of the

equipment

X

85052_par_Stromerzeuger_Content_LB7_HR_RO_BG_GR.indd 13

20.11.12 11:51

Advertising